您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > PLC > 1769-L20, 1769-L30 CompactLogixControllers Installation Instructions

1769-L20, 1769-L30 CompactLogixControllers Installation Instructions

  • 小库
  • 130 人阅读
  • 0 人下载
  • 2019-02-20 11:06:04
VIP免费

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有130人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

Publication 1769-IN047C-EN-P - April 2003Installation Instructions1769-L20, 1769-L30 CompactLogix™ Controllers(Cat. No. 1769-L20, 1769-L30)Inside...Before You Begin.................................................................................... 2For More Information.............................................................................. 2European Communities (EC) Directive Compliance................................ 4Hazardous Location Considerations....................................................... 5CompactLogix Controller Description..................................................... 6System Planning..................................................................................... 6Install the Controller............................................................................... 7Connect the Battery................................................................................ 8Assemble the System............................................................................. 9Mount the System................................................................................ 10Grounding Considerations.................................................................... 12Select the Controller’s Operating Mode............................................... 12RS-232 Connections to the Controller.................................................. 13Default Communication Configuration................................................. 14Using the Channel 0 Default Communication Push Button.................. 15Troubleshoot the Controller Using the LEDs......................................... 16Flash Upgrade the Controller Firmware................................................ 17Specifications....................................................................................... 18Dimensions........................................................................................... 19Battery Handling, Storing, and Transporting........................................ 202 1769-L20, 1769-L30 CompactLogix™ Controllers Publication 1769-IN047C-EN-P - April 2003Before You BeginUse this document as a guide for installing and powering-up your 1769-L20, -L30 CompactLogix controller system. You should already be familiar with the CompactLogix system components.You must FLASH upgrade the firmware on your CompactLogix controller before you can use it. The controller ships with firmware revision 1.x but must be upgraded to match the version of RSLogix 5000 that you are using (e.g. if you are using RSLogix 5000 V11, you must upgrade your CompactLogix controller firmware to revision 11.x before using it. For more information on upgrading your controller’s firmware, see page 17.For More Information If you would like a manual, you can obtain it as follows:�download a free electronic version from the internet: �www.theautomationbookstore.com�purchase a printed manual by:–contacting your local distributor or Rockwell Automation representative–visiting www.theautomationbookstore.com and placing your order–calling 1.800.963.9548 (USA/Canada) �or 001.330.725.1574 (Outside USA/Canada)For Information onRefer to this DocumentPub. No.How to use 1769-L20, -L30 CompactLogix™ controllersCompactLogix™ System User Manual1769-UM007Programming the controllerLogix5000™ Controllers Common Procedures Programming Manual1756-PM001General instructionsLogix5000 Controller General Instructions Reference Manual1756-RM003Process control and drives instructionsLogix5000 Controller Process Control and Drives Instructions Reference Manual1756-RM006Installing and operating Compact power suppliesCompact™ 1769 Expansion I/O Power Supplies Installation Instructions1769-IN028Installing and operating Compact I/OCompact 1769 Expansion I/O Installation Instructions for your particular moduleInstalling and operating Compact I/O analog modulesCompact 1769 I/O Analog Modules User Manual1769-UM002How to use the 1769-ADN DeviceNet adapter moduleDeviceNet Adapter Module User Manual1769-UM001Proper wiring and grounding techniques.Industrial Automation Wiring and Grounding Guidelines1770-4.11769-L20, 1769-L30 CompactLogix™ Controllers 3Publication 1769-IN047C-EN-P - April 2003Important User InformationBecause of the variety of uses for the products described in this publication, those responsible for the application and use of these products must satisfy themselves that all necessary steps have been taken to assure that each application and use meets all performance and safety requirements, including any applicable laws, regulations, codes and standards. In no event will Rockwell Automation be responsible or liable for indirect or consequential damage resulting from the use or application of these products.Any illustrations, charts, sample programs, and layout examples shown in this publication are intended solely for purposes of example. Since there are many variables and requirements associated with any particular installation, Rockwell Automation does not assume responsibility or liability (to include intellectual property liability) for actual use based upon the examples shown in this publication.Allen-Bradley publication SGI-1.1, Safety Guidelines for the Application, Installation and Maintenance of Solid-State Control (available from your local Rockwell Automation office), describes some important differences between solid-state equipment and electromechanical devices that should be taken into consideration when applying products such as those described in this publication.Reproduction of the contents of this copyrighted publication, in whole or part, without written permission of Rockwell Automation, is prohibited.Throughout this publication, notes may be used to make you aware of safety considerations. The following annotations and their accompanying statements help you to identify a potential hazard, avoid a potential hazard, and recognize the consequences of a potential hazard:!WARNINGIdentifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.ATTENTION!Identifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss.IMPORTANTIdentifies information that is critical for successful application and understanding of the product.4 1769-L20, 1769-L30 CompactLogix™ Controllers Publication 1769-IN047C-EN-P - April 2003European Communities (EC) Directive ComplianceIf this product has the CE mark it is approved for installation within the European Union and EEA regions. It has been designed and tested to meet the following directives.EMC DirectiveThis product is tested to meet the Council Directive 89/336/EC Electromagnetic Compatibility (EMC) by applying the following standards, in whole or in part, documented in a technical construction file:�EN 50081-2 EMC — Generic Emission Standard, Part 2 — Industrial Environment�EN 50082-2 EMC — Generic Immunity Standard, Part 2 — Industrial EnvironmentThis product is intended for use in an industrial environment.Low Voltage DirectiveThis product is tested to meet Council Directive 73/23/EEC Low Voltage, by applying the safety requirements of EN 61131-2 Programmable Controllers, Part 2 - Equipment Requirements and Tests. For specific information required by �EN 61131-2, see the appropriate sections in this publication, as well as the Allen-Bradley publication Industrial Automation Wiring and Grounding Guidelines For Noise Immunity, publication 1770-4.1. and the Automation Systems Catalog, publication B111.This equipment is classified as open equipment and must be mounted in an enclosure during operation to provide safety protection.1769-L20, 1769-L30 CompactLogix™ Controllers 5Publication 1769-IN047C-EN-P - April 2003Hazardous Location ConsiderationsThis equipment is suitable for use in Class I, Division 2, Groups A, B, C, D or non-hazardous locations only. The following WARNING statement applies to use in hazardous locations.Environnements dangereuxCet équipement est conçu pour être utilisé dans des environnements de Classe 1, Division 2, Groupes A, B, C, D ou non dangereux. La mise en garde suivante s’applique à une utilisation dans des environnements dangereux.!WARNINGEXPLOSION HAZARD�Substitution of components may impair suitability for Class I, Division 2.�Do not replace components or disconnect equipment unless power has been switched off or the area is known to be non-hazardous.�Do not connect or disconnect components unless power has been switched off or the area is known to be non-hazardous.�This product must be installed in an enclosure. All cables connected to the product must remain in the enclosure or be protected by conduit or other means.�All wiring must comply with N.E.C. article 501-4(b).AVERTISSEMENT!DANGER D’EXPLOSION�La substitution de composants peut rendre cet équipement impropre à une utilisation en environnement de Classe 1, Division 2.�Ne pas remplacer de composants ou déconnecter l'équipement sans s'être assuré que l'alimentation est coupée et que l'environnement est classé non dangereux.�Ne pas connecter ou déconnecter des composants sans s'être assuré que l'alimentation est coupée ou que l'environnement est classé non dangereux.�Ce produit doit être installé dans une armoire.

小库

523篇文档

文档介绍: 1769-L20, 1769-L30 CompactLogixControllers Installation Instructions

评论

发表评论
< /24 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功