您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > 变频驱动 > 台安(TAIAN)变频器S310-EN

台安(TAIAN)变频器S310-EN

  • 小库
  • 25 人阅读
  • 0 人下载
  • 2019-06-05 01:10:04

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有25人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

Microprocessor Controlled I G B T Drive Inverter Motor Speed RegulatorOperating Manual S310 Serise 200V class 0.4~1.5KW (0.88~2.9KVA) i S310 Table of Contents Chapter 0 Preface 0-1 0.1 Preface 0-1 0.2 Product Inspection 0-1 Chapter 1 Safety Precautions 1-1 1.1 Operation Precautions 1-1 1.1.1 Before Power UP 1-1 1.1.2 During Power UP 1-2 1.1.3 Before Operation 1-2 1.1.4 During Operation 1-2 1.1.5 During Maintenance 1-3 Chapter 2 Definition of Model 2-1 Chapter 3 Ambient Environment and Installation 3-1 3.1 Environment 3-1 3.2 Environmental Precautions 3-2 3.3 Electrical Installation 3-3 3.3.1 Wiring guidelines 3-3 3.3.2 Contactor and Circuit Breaker specification and wiring 3-4 3.3.3 Precautions for Peripheral Applications 3-5 3.4 Specifications 3-8 3.4.1 Product Specifications 3-8 3.4.2 General Specifications 3-8 3.5 Wiring Diagram S310 Series Inverter 3-103.6 Description of connection terminals 3-113.7 Outline Dimension 3-13Chapter 4 Software Index 4-1 4.1 Keypad Description 4-1 4.2 S310 Programmable Functions List 4-3 4.3 Parameter Function Description 4-11Chapter 5 Troubleshooting and Maintenance 5-1 5.1 Error Display and Corrective Action 5-1 5.1.1 Error Display and Corrective Action 5-1 5.1.2 Special conditions 5-2 5.1.3 Operation errors 5-3 5.1.4The instructions for the Power and Alarm LED of the inverter 5-3 5.2 General Troubleshooting 5-4 5.3 Quick troubleshooting of S310 series 5-5 5.4 Routine and periodic inspection 5-115.5 Maintenance and Inspection 5-12Chapter 6 Peripheral Components 6-1 6.1 AC reactor and DC reactor specification at input side 6-1 6.2 Digital operator and extension cable 6-1 AppendixⅠ S310 Parameters Setting List App1 ii Index of Figures Figure 2-1 Inverter Nameplate.....................................................................................2-1 Figure 3-1 Panel and enclosure arrangement for S310 inverters ...................................3-1 Figure 3-2 Din rail mounting of the S310 inverter.........................................................3-1 Figure 3-3 Typical Installation Schematic.....................................................................3-5 Figure 3-4a) Installation Examples...............................................................................3-6 b) Installation Examples Using a Filter and Isolation transformer ................3-6 c) Installation Examples with Adjacent Signal Conductors ...........................3-6 Figure 3-5 Control Cable requirements........................................................................3-7 Figure 3-6 Grounding Examples ..................................................................................3-7 Figure 3-7 Wiring Diagram.......................................................................................... 3-10 Figure 3-8 Power Input Locations................................................................................ 3-12 Figure 3-9 Frame size 1 Dimensions ............................................................................. 3-13 Figure 3-10 Frame size 2 Dimensions ........................................................................... 3-14 Figure 3-11 Frame size 3 Dimensions ........................................................................... 3-15 Figure 3-12 Frame size 4 Dimensions ........................................................................... 3-16 Figure 3-13 Frame size 5 Dimensions ........................................................................... 3-17 Figure 3-14 Frame size 6 Dimensions ........................................................................... 3-18 Figure 4-1 Keypad Layout ...........................................................................................4-1 Figure 4-2 LED Keypad Operations Sequence..............................................................4-2 Figure 4-3 Frequency reference limits .......................................................................... 4-11 Figure 4-4 Terminal Board Drive Operation Modes ..................................................... 4-12 Figure 4-5 3-Wires Start/Stop Wiring........................................................................... 4-12 Figure 4-6 Drive Start/Stop Operation sequences ......................................................... 4-12 Figure 4-7 Frequency within specified range example................................................... 4-15 Figure 4-8 Frequency outside of range example............................................................ 4-15 Figure 4-9 Frequency at or below specified range example ........................................... 4-15 Figure 4-10 Analog scaling examples ....................................................................................4-1616 Figure 4-11 DC Injection Braking Example..........................................................................4-20 Figure 4-12 Custom V/F settings ............................................................................................4-21 Figure 4-13 V/F curve with torque boost...............................................................................4-22 Figure 4-14 Single cycle auto run ...........................................................................................4-27 Figure 4-15 Periodic cycle auto run........................................................................................4-27 Figure 4-16 Single cycle auto run: final step hold.................................................................4-28 Figure 4-17 AUTO_RUN cycle with interrupt......................................................................4-28 Figure 5-1 S310 Fault Display and Troubleshooting Flow Chart .......................................5-6 Figure 5-2 OC, OL Fault Display Flow Chart.......................................................................5-7 Figure 5-3 OV, LV Fault Display Flow Chart.......................................................................5-8 Figure 5-4 Motor RUN failure Flow chart ........................................................................... 5-9 Figure 5-5 Motor Overheat Troubleshooting Flow Chart ...................................................5-10 Figure 5-6 Motor Instability Troubleshooting Flow Chart ............................................ 5-10 Figure 6-1 Digital Operator Extension Cable........................................................................6-1 Preface 0-1 Chapter 0 Preface 0.1 Preface To extend the performance of the product and ensure personnel safety, please read this manual thoroughly before using the inverter. Should there be any problem in using the product that can not be solved with the information provided in the manual, contact your nearest TECO’s technical or sales representative who will be willing to help you. ※Precautions The inverter is an electrical product. For your safety, there are symbols such as “Danger”, “Caution” in this manual as a reminder to pay attention to safety instructions on handling, installing, operating, and checking the inverter. Be sure to follow the instructions for highest safety. Danger Indicates a potential hazard that could cause death or serious personal injury if misused. Caution Indicates that the inverter or the mechanical system might be damaged if misused. Danger � Do not touch any circuit boards or components after the power is turned off and while the charging indicator is still lit. (The light will fade) � Do not make any connections when the inverter is powered on. Do not check parts and signals on circuit boards during the inverter operation. � Do not disassemble the inverter or modify any internal wires, circuits, or parts. ● Ground the ground terminal of the inverter properly. For 200V class ground resistance 100 Ω or below. For 400V class 10Ω or below. Caution � Do not perform a voltage test on parts inside the inverter. High voltage can destroy the semiconductor components. � Do not connect U, V, and W terminals of the inverter to any AC input power supply. � CMOS ICs on the inverter’s main board are susceptible to static electricity. Do not touch the main circuit board 0.2 Product Inspection TECO inverters have all passed the function test before delivery. Please check the following when you receive and unpack the inverter: � The model of the inverter are the same as those specified in your purchase order. � Check for any damages caused by transportation. Please do not apply power, and contact a TECO sales representative if any of the above problems occurred. Chapter 1 Safety Precautions 1-1 Chapter 1 Safety Precautions 1.1 Operation Precautions 1.1.1. Before Power Up Caution The line voltage applied must comply with the inverter’s specified input voltage.(See product nameplate) Danger Make sure the main circuit connections are correct. L1, L2 and are power-input terminals and must not be mistaken for U, V and W. Otherwise, inverter damage can result. Caution � To avoid the front cover from disengaging or other damage, do not carry the inverter by its cover. Support the drive by its heat sink when transporting. Improper handling can damage the inverter or injure personnel, and should be avoided. � To avoid the risk of fire, do not install the inverter on flammable objects. Install on nonflammable objects such as metal surfaces. � If several inverters are placed in the same control panel, provide heat extraction means to keep the temperature below 40℃ to avoid overheat or fire hazard. � When removing or installing the operator keypad, turn OFF the power first, and secure the keypad correctly to avoid keypad operation or display failure. Warning This product is sold subject to IEC 61800-3. In a domestic environment this product may cause radio interference in which case the user may be required to apply corrective measures.

小库

516篇文档

文档介绍: 台安(TAIAN)变频器S310-EN

相关搜索

变频器 台安 TAIAN S310 EN

评论

发表评论
< /71 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功