您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > 其他 > XLt OCS Model HE-XT102 HEXT240C112 HEXT240C012

XLt OCS Model HE-XT102 HEXT240C112 HEXT240C012

  • 文哥
  • 62 人阅读
  • 0 人下载
  • 2019-05-02 11:46:19

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有62人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

MAN0869-06-EN Specifications / Installation __________________________________________________________________________________________________________________________________________________________________ 12/17/2008 Page 1 of 4 ECN # 947 1 Specifications 1 Specifications XLt OCS Model: HE-XT102 / HEXT240C112 / HEXT240C012 12 Digital DC Inputs 4 Analog Inputs (Medium Resolution) 6 Digital Relay Outputs Specifications Digital DC Inputs Inputs per Module 12 including 4 configurable HSC inputs Commons per Module 1 Input Voltage Range 12 VDC / 24 VDC Absolute Max. Voltage 35 VDC Max. Input Impedance 10 kΩ Input Current Positive LogicNegative LogicUpper Threshold 0.8 mA -1.6 mA Lower Threshold 0.3 mA -2.1 mA Max Upper Threshold 8 VDC Min Lower Threshold 3 VDC OFF to ON Response 1 ms ON to OFF Response 1 ms HSC Max. Switching Rate 10 kHz Totalizer/Pulse, Edges 5 kHz Frequency/Pulse, Width 2.5 kHz Quadrature Digital Relay Outputs Outputs per Module 6 relay Commons per Module 6 Max. Output Current per Relay 3 A at 250 VAC, resistive Max. Total Output Current 5 A continuous Max. Output Voltage 275 VAC , 30 VDC Max. Switched Power 1250 VA, 150 W Contact Isolation to XLe ground 1000 VAC Max. Voltage Drop at Rated Current 0.5 V Expected Life (See Derating section for chart.) No load: 5,000,000 Rated load: 100,000 Max. Switching Rate 300 CPM at no load 20 CPM at rated load Type Mechanical Contact Response Time One update per ladder scan plus 10 ms Analog Inputs, Medium Resolution Number of Channels 4 Input Ranges 0 - 10 VDC 0 – 20 mA 4 – 20 mA Safe input voltage range -0.5 V to +12V Input Impedance (Clamped @ -0.5 VDC to 12 VDC) Current Mode: 100 Ω Voltage Mode: 500 k Ω Nominal Resolution 10 Bits %AI full scale 32,000 counts Max. Over-Current 35 mA Conversion Speed All channels converted once per ladder scan Max. Error at 25°C (excluding zero) *can be made tighter (~0.25%) by adjusting the digital filter setting to 3. 4-20 mA 1.00% 0-20 mA 1.00% 0-10 VDC 1.50%* Additional error for temperatures other than 25°C TBD Filtering 160 Hz hash (noise) filter 1-128 scan digital running average filter General Specifications Required Power (Steady State) 130 mA @ 24 VDC Required Power (Inrush) 30 A for 1 ms @ 24 VDC Primary Power Range 10 – 30 VDC Relative Humidity 5 to 95% Non-condensing General Specifications continued Operating Temperature -10°C to +60°C Terminal Type Screw Type, 5 mm Removable Weight 12 oz. (340.19 g) CE Clock Accuracy +/- Seven Minutes/Month at 20C UL See Compliance Table at http://www.heapg.com/Pages/TechSupport/ProductCert.html 2 Panel Cut-Out and Dimensions Note: Max. panel thickness: 5 mm. Refer to the XLe/XLt User Manual for panel box information and a handy checklist of requirements. Note: The tolerance to meet NEMA standards is ± 0.005” (0.1 mm). 3.622 [92mm]3.622 [92mm]001XLE002 Note – Your keypad overlay appearance may differ. Standard US/EU overlays pictured here for example. 3 Ports / Connectors / Cables Note: The case of the XLt is black, but for clarity, it is shown in a lighter gray color. To Remove Back Cover: Power Connector Power Up: Connect to Earth Ground. Apply 10 - 30 VDC. Screen lights up. Torque rating 4.5 – 7 Lb-In (0.50 –0.78 N-m) CAN Connector Use the CAN Connector when using CsCAN network. Torque Rating 4.5 – 7 Lb-In (0.50 – 0.78 N-m) Unscrew 4 screws located on the back of the unit. Remove cover.CAUTION: Do notover tighten screws when replacing the back cover. I/O Jumpers: (Not Shown): I/O Jumpers (JP) are located internally. To access, remove back cover of unit. MJ1(RS-232 / RS-485)MJ2(RS-232 / RS-485)J1I/O JumperMemory Slot001XLE029-R2 J2I/O Jumper NET 1(CsCAN)PowerDIPSwitch Wiring Connectors (J1 / J2): I/O Jumpers (JP1 / JP2), andExternal Jumpers (RS-485) are described in the Wiring and Jumpers section of this document. Memory Slot: Uses Removable Memory for data logging, screen captures, program loading and recipes. Horner Part No.: HE-MC1 Serial Communications: MJ1: (RS-232 / RS-485) Use forCscape programming and Application-Defined Communications. MJ2: (RS-232 / RS-485) Use for Application-Defined Communications. Note: Highest usable frequency for PWM output is 65 KHz MAN0869-06-EN Specifications / Installation __________________________________________________________________________________________________________________________________________________________________ 12/17/2008 Page 2 of 4 ECN # 947 4 Wiring and Jumpers Wire according to the type of inputs / outputs used, and select the appropriate jumper option. 4.1 Wiring Examples J1 Orange Terminal Connector Name I1 IN1 I2 IN2 I3 IN3 I4 IN4 I5 IN5 I6 IN6 I7 IN7 I8 IN8 H1 HSC1 /IN9 0V Ground A1 Analog IN1 A2 Analog IN2 A3 Analog IN3 A4 Analog IN4 0V Ground 4.2 Wiring Examples (continued) J2 Black Terminal Connector Name C6 Relay 6 COM R6 Relay 6 NO C5 Relay 5 COM R5 Relay 5 NO C4 Relay 4 COM R4 Relay 4 NO C3 Relay 3 COM R3 Relay 3 NO C2 Relay 2 COM R2 Relay 2 NO C1 Relay 1 COM R1 Relay 1 NO H4 HSC4 / IN12 H3 HSC3 / IN11 H2 HSC2 / IN10 4.3 I/O Jumpers Settings (JP1 - JP2) 4.4 External DIP Switch Settings Note: The Cscape Module Setup configuration must match the selected I/O (JP) jumper settings. JP1 Digital DC In / HSCPositive Negative Logic Logic Default A1 A2 A3 A4JP2 Analog In (A1 – A4) Current Voltage (20 mA) (10 V) Default J1JP2JP1J2001XLE025Location of I/O jumpers (JP) and wiring connectors (J1 and J2). I10V001XLE03612-24VDCI10VPositive Logic In Negative Logic In Positive Logic vs. Negative Logic Wiring The XLt can be wired for Positive Logic inputs or Negative Logic inputs. 001XLE0150V ON J112-24VDCR2C2R3C3R6C6R4C4R5C5R1C1H4H2H3LOAD230VACOR25VDCNLLOAD230VACOR25VDCNLLOAD230VACOR25VDCNLLOAD230VACOR25VDCNLLOAD230VACOR25VDCNLLOAD230VACOR25VDCNLJ2 Black Positive Logic Digital In / Relay Out Wiring Specifications �For I/O wiring (discrete), use the following wire type or equivalent: Belden 9918, 18 AWG (0.8 mm2) or larger. �For shielded Analog I/O wiring, use the following wire type or equivalent: Belden 8441, 18 AWG (0.8 mm2) or larger. �For CAN wiring, use the following wire type or equivalent: Belden 3084, 24 AWG (0.2 mm2) or larger. Use copper conductors in field iil60/75°C The External DIP Switches are used for termination of the RS-485 ports. The XLt is shipped un-terminated. To terminate, select one of the jumpers shipped with the product and insert it based upon the option that is desired or, select the switch and configure based upon the option that is desired. As seen when looking at the top of the XLt unit XT102 J1 Orange Positive Logic In Digital In / Analog In I1I2I3I40VA1A20VI5I6I7I8A3A4H1001XLE01712-24VDCLOOP PWR20mA0-10VDCNote: When using JP2 (A1-A4), each channel can be independently configured. Note: Loop Power requirements are determined by the transmitter specification. Pin MJ1 Pins MJ2 Pins Signal Direction Signal Direction 8 TXD OUT TXD OUT 7 RXD IN RXD IN 6 0 V Ground 0 V Ground 5* +5 60mA OUT +5 60mA OUT 4 RTS OUT TX- OUT 3 CTS IN TX+ OUT 2 RX- / TX- IN / OUT RX- IN 1 RX+ / TX+ IN / OUT RX+ IN 1 8 Serial Communications: MJ1: (RS-232 / RS-485) Use for Cscape programming and Application-Defined Communications. MJ2: (RS-232 / RS-485) Use for Application-Defined Communications. DIPSW3: FACTORY USE ONLY (tiny bootloader firmware downloading). NOT TO BE USED FOR NORMAL OCS OPERATION. DIPSW2: MJ2 Termination (default – none) DIPSW1: MJ1 Termination (default – none) 001XLE037-R1* +5Vdc 60mA Max MAN0869-06-EN Specifications / Installation __________________________________________________________________________________________________________________________________________________________________ 12/17/2008 Page 3 of 4 ECN # 947 5 MJ2 Pinouts in Full and Half Duplex Modes 6 Filter Filter Constant sets the level of digital filtering according to the following chart. Digital Filtering. The illustration above demonstrates the effect of digital filtering (set with Filter Constant) on module response to a temperature change. 7 Derating Pin MJ2 Pins Signal Direction 8 TXD OUT 7 RXD IN 6 0 V Ground 5* +5 60mA OUT 4 TX- OUT 3 TX+ OUT 2 RX- IN 1 RX+ IN 1 8 * +5Vdc 60mA Max MJ2 Full Duplex Mode MJ2 Half Duplex Mode Pin MJ2 Pins Signal Direction 8 TXD OUT 7 RXD IN 6 0 V Ground 5* +5 60mA OUT 4 TX- OUT 3 TX+ OUT 2 TX-/RX- IN/OUT 1 TX+/RX+ IN/OUT 18* +5Vdc 60mA Max 8 I/O Register Map Registers Description 602010040802001010090807060504030Scans012345607%Complete [ ]FilterConstant%I1 to %I24 Digital Inputs %I32 Output Fault %I25 to %I31 Reserved %Q1 to %Q16 Digital outputs %Q17 Clear HSC1 accumulator to 0 Totalizer: Clear HSC2 %Q18 Quadrature 1-2: Accumulator 1 Reset to max – 1 %Q19 Clear HSC3 Accumulator to 0 Totalizer: Clear HSC4 %Q20 Quadrature 3-4: Accumulator 3 Reset to max – 1 %Q21 to %Q32 Reserved %AI1 to %AI4 Analog inputs %AI5, %AI6 HSC1 Accumulator %AI7, %AI8 HSC2 Accumulator %AI9, %AI10 HSC3 Accumulator %AI11, %AI12 HSC4 Accumulator %AQ1, %AQ2 PWM1 Duty Cycle %AQ3, %AQ4 PWM2 Duty Cycle %AQ5, %AQ6 PWM Prescale %AQ7, %AQ8 PWM Period %AQ9 to %AQ14 Analog outputs Note: Not all XLt units contain the I/O listed in this table. Relay Life Expectancy0102030401234Contact Current (A)Operation (x104)MAN0869-06-EN Specifications / Installation __________________________________________________________________________________________________________________________________________________________________ 12/17/2008 Page 4 of 4 ECN # 947 9 Safety When found on the product, the following symbols specify: Warning: Consult user documentation. Warning: Electrical Shock Hazard. This equipment is suitable for use in Class I, Division 2, Groups A, B, C and D or Non-hazardous locations only WARNING – EXPLOSION HAZARD – Substitution of components may impair suitability for Class I, Division 2 AVERTISSEMENT - RISQUE D'EXPLOSION - LA SUBSTITUTION DE COMPOSANTS PEUT RENDRE CE MATERIAL INACCEPTABLE POUR LES EMPLACEMENTS DE CLASSE 1, DIVISION 2 WARNING – EXPLOSION HAZARD – Do not disconnect equipment unless power has been switched off or the area is known to be non-hazardous. AVERTISSEMENT - RISQUE D'EXPLOSION - AVANT DE DECONNECTOR L'EQUIPMENT, COUPER LE COURANT OU S'ASSURER QUE L'EMPLACEMENT EST DESIGNE NON DANGEREUX. WARNING: To avoid the risk of electric shock or burns, always connect the safety (or earth) ground before making any other connections. WARNING: To reduce the risk of fire, electrical shock, or physical injury it is strongly recommended to fuse the voltage measurement inputs. Be sure to locate fuses as close to the source as possible. WARNING: Replace fuse with the same type and rating to provide protection against risk of fire and shock hazards. WARNING: In the event of repeated failure, do not 10 Technical Support For assistance and manual updates, contact Technical Support at the following locations: North America: (317) 916-4274 www.heapg.com email: techsppt@heapg.com Europe: (+) 353-21-4321-266 www.horner-apg.com email: techsupport@hornerirl.ie No part of this publication may be reproduced without the prior agreement and written permission of Horner APG, Inc. Information in this document is subject to change without notice. replace the fuse again as a repeated failure indicates a defective condition that will not clear by replacing the fuse. WARNING: Only qualified electrical personnel familiar with the construction and operation of this equipment and the hazards involved should install, adjust, operate, or service this equipment. Read and understand this manual and other applicable manuals in their entirety before proceeding. Failure to observe this precaution could result in severe bodily injury or loss of life. This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference. 2. This device must accept any interference received, including interference that may cause undesired operation. � All applicable codes and standards need to be followed in the installation of this product. � Adhere to the following safety precautions whenever any type of connection is made to the module: � Connect the safety (earth) ground on the power connector first before making any other connections. � When connecting to electric circuits or pulse-initiating equipment, open their related breakers. � Do not make connections to live power lines. � Make connections to the module first; then connect to the circuit to be monitored. � Route power wires in a safe manner in accordance with good practice and local codes. � Wear proper personal protective equipment including safety glasses and insulated gloves when making connections to power circuits. � Ensure hands, shoes, and floor are dry before making any connection to a power line. � Make sure the unit is turned OFF before making connection to terminals. � Make sure all circuits are de-energized before making connections. � Before each use, inspect all cables for breaks or cracks in the insulation. Replace immediately if defective. • Use Copper Conductors in Field Wiring Only, 60/75° C "WARNING: EXPOSURE TO SOME CHEMICALS MAY DEGRADE THE SEALING PROPERTIES OF MATERIALS USED IN THE Tyco relay PCJ Cover / case & base: Mitsubishi engineering Plastics Corp. 5010GN6-30 or 5010GN6-30 M8 (PBT) Sealing Material: Kishimoto 4616-50K (I part epoxy resin) It is recommended to periodically inspect the relay for any degradation of properties and replace if degradation is found

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: XLt OCS Model HE-XT102 HEXT240C112 HEXT240C012

评论

发表评论
< /4 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功