您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > PLC > RSLogix 5000 Software Release History Installation Notes

RSLogix 5000 Software Release History Installation Notes

  • 文哥
  • 27 人阅读
  • 0 人下载
  • 2019-02-22 23:30:23

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有27人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

 RSLogix 5000 Software Release History RSLogix 5000 Software Release History Installation Notes Review these notes before attempting to install this version of the RSLogix 5000 software. Prior to Installation Keep the following considerations in mind before you install the RSLogix 5000 software:  Be certain that no copies of RSLogix 5000 software are currently running.  Make sure that you have Administrator privileges on the personal computer on which you want to install the software. You will not be able to complete the installation without these privileges.  If you want to perform online communications, you must install RSLinx Classic software in addition to RSLogix 5000 software.  Close all other applications before running the setup process.  Ensure that there are no pending workstation reboot requests from either Windows Update or any installation program. If there is a pending request, reboot the workstation before starting the RSLogix 5000 installation.  Refer to the Choosing Your RSLogix 5000 Package section of this document to determine which controllers are supported by your RSLogix 5000 Enterprise Series bundle. Installing the Software Follow these steps to install RSLogix 5000 software. 1. Start your personal computer. 2. Insert the RSLogix 5000 installation DVD into your DVD-ROM drive. The DVD-ROM should auto-start. If it does not auto-start, run Setup.exe from the root of the DVD. RSLogix 5000 Enterprise Series software supports multiple versions of the programming software on a single personal computer. With RSLogix 5000 software version 10 and later, you may install as many of the later major versions as needed plus one version earlier than version 10 (for example, version 8.02). 3. Follow the directions that appear on your screen. Note that RSLogix 5000 software version 20 may need to update several system files early in the installation process. These updates will likely require you to restart your personal computer. Be sure to close all other applications before clicking OK to initiate this reboot. When prompted for a serial number, enter the 10-digit serial number identifying your software license; otherwise, enter any sequence of characters, not longer than 10 characters. Use the F1 key if you need help. Important: The 10-digit serial number is used to determine what functionality to enable while in Grace Period mode. Entering an invalid serial number will result in the software operating in Service Edition mode, upload/download only, while in Grace Period mode. 4. When prompted, click Yes to complete the activation of the software. 5. Follow the directions that appear on your screen and refer to the FactoryTalk Activation insert for additional information. Important: When a valid activation cannot be located by the software, the software will enter a seven-day activation grace period, during which you will be able to run the software with full functionality. If this seven-day grace period ends before a valid activation has been found, you will no longer be able to start the RSLogix 5000 software. 6. Click Finish to complete the installation. When the setup utility finishes, an entry for the RSLogix 5000 application program appears in the program list in the Rockwell Software group. 7. Remove the RSLogix 5000 DVD from the DVD-ROM drive and store it in a safe place.  RSLogix 5000 Software Release History Starting RSLogix 5000 Software To start RSLogix 5000 software, from the Start menu, choose All Programs>Rockwell Software>RSLogix 5000 Enterprise Series>RSLogix 5000 from the menu. If RSLogix 5000 software does not start up or run properly, keep the following in mind:  Do you have the correct version of RSLinx Classic software installed? RSLinx Classic software provides communication between the controller and your personal computer.  Does your computer have enough memory? Running RSLogix 5000 software requires a minimum of 512 MB of RAM. Tip Remember to use the Help function from within the application if you need help with a specific dialog box or function. Press [F1] or click the Help button on a dialog box, or select Help from the menu bar.  RSLogix 5000 Software Release History Uninstalling the Software Follow these steps to uninstall the software when using the default „Start menu‟ on the Windows 7, Windows Vista, Windows XP, or Windows Server 2008 operating system. 1. From the Start menu, choose Control Panel. 2. From the Programs category, choose Uninstall a program. (for Windows 7, Windows Server 2008 R2) From the Programs category, choose Uninstall a program. (for Windows Vista, Windows Server 2008 – Control Panel Home) Double-click Programs and Features. (for Windows Vista, Windows Server 2008 – Classic View) Double-click Add or Remove Programs. (for Windows XP – Classic View) Click Add or Remove Programs. (for Windows XP – Category View) 3. From this dialog box, double-click RSLogix 5000 <version>. Follow these steps to uninstall the software when using the „Classic Start‟ menu on the Windows XP operating system and later. 1. From the Start menu, choose Settings>Control Panel. 2. From the Programs category, choose Uninstall a program. (for Windows Vista, Windows Server 2008 – Control Panel Home) Double-click Programs and Features. (for Windows Vista, Windows Server 2008 – Classic View) Double-click Add or Remove Programs. (for Windows XP, Windows Server 2003 – Classic View) Click Add or Remove Programs. (for Windows XP – Category View) 3. From this dialog box, double-click RSLogix 5000 <version>. Follow these steps to uninstall the software when using the default „Start menu‟ on the Windows Server 2003 operating system. 1. From the Start menu, choose Settings>Control Panel>Add or Remove Programs. 2. From this dialog box, double-click RSLogix 5000 <version>. You will be prompted to decide whether you wish to preserve any application settings you have previously configured. Follow the prompts of the uninstaller, and RSLogix 5000 software will be uninstalled from your computer. Note that this will uninstall only the RSLogix 5000 application. Other components that were installed with RSLogix 5000 software (such as Start Page Media, Online Books, or RSLinx) must be uninstalled separately.  RSLogix 5000 Software Release History System Requirements The personal computer must meet these minimum requirements. Using a computer meeting or exceeding the recommended characteristics will improve performanc Hardware Requirements The personal computer must meet these minimum requirements. Using a computer meeting the recommended characteristics will improve performance. Characteristic Minimum Recommended Processor Pentium 4 Intel Core i5 Speed 2.8 GHz 2.4 GHz RAM Memory 1 GB 8 GB Hard Disk Space 16 GB free 20 GB free Graphics Device 1024x768, True Color DirectX 9, with WDDM 1.0 or higher driver Software Requirements Operating system and service pack compatibility:  This version of RSLogix 5000 software has been tested on the following operating systems:  Microsoft Windows 7 Professional (64-bit) with Service Pack 1  Microsoft Windows 7 Home Premium (64-bit) with Service Pack 1  Microsoft Windows 7 Home Premium (32-bit) with Service Pack 1  Microsoft Windows Vista Business (32-bit) with Service Pack 2  Microsoft Windows XP Professional with Service Pack 3  Microsoft Windows Server 2008 R2 Standard Edition with Service Pack 1  Microsoft Windows Server 2008 Standard Edition with Service Pack 2  Microsoft Windows Server 2003 R2 Standard Edition with Service Pack 2  This version of RSLogix 5000 software is expected to operate correctly on all other editions and service packs of the following operating systems but has not been tested:  Microsoft Windows 7  Microsoft Windows Vista  Microsoft Windows XP (Service Pack 3 or higher)  Microsoft Windows Server 2008 R2  Microsoft Windows Server 2008  Microsoft Windows Server 2003 For operating systems that support User Account Control (UAC), this version of RSLogix 5000 software was tested with UAC set to the most restrictive level (“Always notify” for Windows 7, or “On” for Vista). This version of RSLogix 5000 software is also expected to operate correctly when UAC is configured for any less restrictive setting. RSLogix 5000 software versions earlier than version 19 are not supported on Microsoft Windows 7 operating systems at this time and have not been tested on those operating systems. RSLogix 5000 software versions earlier than version 17 are not supported on Microsoft Windows Vista operating systems at this time and have not been tested on those operating systems. RSLogix 5000 software version 17 is supported on a Microsoft Windows Vista operating system only when User Account Control (UAC) is turned off. Running RSLogix 5000 software in conjunction with Fast-User Switching is not supported. Running RSLogix 5000 software in Safe mode is not supported. Running RSLogix 5000 software via Remote Desktop is not supported. Additional Software Product Considerations  FactoryTalk Services Platform 2.50 or later is not required to run RSLogix 5000 software; however it is required in order to perform some security functions in RSLogix 5000 software.  RSLinx Classic communication software is not required to install RSLogix 5000 software; however it is required in order to perform online communication with controllers.  FactoryTalk View SE (CPR 9) software and RSLinx Enterprise communication software are not required to install RSLogix 5000 software; however these products are required in order to fully use the alarm capabilities introduced with version 16.  Be sure to check the software requirements for other Rockwell Software products that you intend to install to be sure that these products are also compatible with the system.  RSLogix 5000 Software Release History Revision Information Supported Logix Controllers While RSLogix 5000 software continues to extend its functionality with each new release, the physical controllers that it supports will vary. New controllers are added, and in some cases support for existing controllers may be removed. While a specific controller may not be supported by the current release, the side-by-side installation of multiple versions of RSLogix 5000 software will in most cases provide a means to support the older hardware. If you decide to migrate from one controller to another, a project created for one controller can be easily converted to another controller via the Controller Properties configuration dialog box within RSLogix 5000 software. Additionally, if you open a project that is configured for a controller that is no longer supported and the older version of RSLogix 5000 software is not installed, RSLogix 5000 software version 13 and later will provide an appropriate warning and will automatically provide the option to convert the project to one of the controllers supported by the release. The following table provides a breakdown of the various Logix5000 controllers and the initial or minimum version of RSLogix 5000 software that is required and, in case the controller is no longer supported, the last or maximum version of RSLogix 5000 software that provided support for the controller. Controller Catalog Number Minimum RSLogix 5000 Major Version Maximum RSLogix 5000 Major Version ControlLogix 1756-L1 1 13 ControlLogix 1756-L53 6 11 ControlLogix 1756-L55 6 16 ControlLogix 1756-L60M03SE 13 17 1 ControlLogix 1756-L61 Series A 12 20 ControlLogix 1756-L61 Series B 12 20 GuardLogix 1756-L61S Series B 14 20 2 ControlLogix 1756-L62 Series A 12 20 ControlLogix 1756-L62 Series B 12 20 GuardLogix 1756-L62S Series B 14 20 2 ControlLogix 1756-L63 Series A 10 20 ControlLogix 1756-L63 Series B 12 20 ControlLogix 1756-L63XT Series B 16 20 GuardLogix 1756-L63S Series B 17 20 ControlLogix 1756-L64 Series B 16 20 ControlLogix 1756-L65 17 20 ControlLogix 1756-L71 Series B 20 Current ControlLogix 1756-L71S Series B 20.01 Current ControlLogix 1756-L72 Series A 19 Current ControlLogix 1756-L72 Series B 20 Current GuardLogix 1756-L72S Series B 20 Current ControlLogix 1756-L73 Series A 18 Current ControlLogix 1756-L73 Series B 20 Current ControlLogix 1756-L73XT Series B 20 Current GuardLogix 1756-L73S Series B 20 Current GuardLogix 1756-L73SXT Series B 20 Current ControlLogix 1756-L74 Series A 19 Current ControlLogix 1756-L74 Series B 20 Current ControlLogix 1756-L75 Series A 18 Current ControlLogix 1756-L75 Series B 20 Current CompactLogix 1768-L43 Series A 15 20 CompactLogix 1768-L43 Series B 16.03 20 CompactLogix 1768-L43S Series A 18 20 CompactLogix 1768-L45 Series A 16.03 20 CompactLogix 1768-L45 Series B 16.03 20 CompactLogix 1768-L45S Series A 18 20 CompactLogix 1769-L16ER-BB1B 20 Current CompactLogix 1769-L18ER-BB1B 20 Current CompactLogix 1769-L18ERM-BB1B 20 Current CompactLogix 1769-L20 7 13 CompactLogix 1769-L23E-QB1 17 20 CompactLogix 1769-L23E-QBFC1 17 20 CompactLogix 1769-L23-QBFC1 17 20

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: RSLogix 5000 Software Release History Installation Notes

评论

发表评论
< /79 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功