 PowerFlex® 4-Class HIM (DSI) Quick ReferenceHuman Interface Modules (HIM) Display Descriptions 22-HIM-A3 — IP20 (NEMA Type 1)22-HIM-C2S — IP66 (NEMA Type 4X/12)Display➊Status Line: Direction | Operating Status | Drive Status | Auto/Manual Mode | Parameters Locked/Unlocked➋Process Display screen:•Output Frequency•User Display Line 1 (HIM Parameter 04)•User Display Line 2 (HIM Parameter 05)➌Programming screen➍Menu Navigation Tabs➎Large Format User Display screen:SelEscEsc789456123.0+/-SelJogAltParam #ViewLangRemoveDSIEscSelALTLANGDISPJog|DSIREMOVEEscSelALTLANGDISPJog|DSISELDIAGDSELMEMChanged ParamsLinear ListParametersGroupsPARAMHzAVF Stopped AutoHzF At Reference AutoOutput Freq➍➎➊➋➌Esc789456123.0+/-SelJogAltParam #ViewLangRemoveDSIHzAVF Stopped Auto Key Descriptions Menu Navigation Tabs KeysDescriptionExit a menu, cancel a change to a parameter value, or acknowledge a fault/alarm.Select a digit, select a bit, or select a menu tab.Scroll through options, increase a value, or toggle a bit.Scroll through options, decrease a value, or toggle a bit.Enter a menu, enter edit mode in a parameter screen, or save a change to a parameter value.plus…Toggle between the Process Display and Large Format Display.Select an available language for text displayed on HIM screens.Allow the HIM to be disconnected without causing a fault condition.Enable direct parameter number entry.Start the drive.Stop the drive or clear a fault.Change direction.Jog the drive.Type parameter numbers and values.Increase or decrease the speed Reference to the drive after these keys are enabled by setting drive parameter P038 - [Speed Reference] as follows:•When the HIM is the DSI Master, set parameter P038 to “5” (Comm Port).•When the HIM is the DSI Slave, set parameter P038 to “1” (Internal Freq).To view the HIM’s active device type status (Master or Slave), see HIM Parameter 10 - [M/S Status].TabsDescriptionDIAGThe Diagnostics tab is used to display faults, the device (drive or peripheral) status, and device version.PARAMThe Parameters tab is used to edit parameters. Parameters can be displayed in groups, in a linear list, or only those changed from their defaults.DSELThe Device Select tab is used to select the device (drive or peripheral) that the HIM is to access.MEMThe Memory Storage tab is used for HIM CopyCat (uploading/downloading configurations to the HIM EEPROM).HIMThe HIM Setup tab is used to access HIM parameters, view the HIM version, and to edit the Reference text when a user-defined Reference is used.EscSelAltSelViewLangRemove+/-Param #Jog...09.+/- Parameter List ParameterNo.Name and DescriptionDetails01[Startup Display]Selects the display screen shown when the HIM is powered up.Default:0 = Main MenuValues0 = Main Menu1 = Process Disp2 = Large Disp3 = Startup ParamType:Read/Write02[Startup Param]Selects a desired drive parameter to be displayed if Parameter 01 - [Startup Display] is set to “3” (Startup Param).Default:1Minimum:1Maximum:65535Type:Read/Write03Reserved04[User Disp Line 1]Selects a desired drive parameter to be displayed on User Display Line 1 of the Process Display screen.For example, setting to “3” selects PowerFlex 4-Class drive Parameter 3 - [Output Current] to be displayed.Default:3Minimum:1Maximum:65535Type:Read/Write05[User Disp Line 2]Selects a desired drive parameter to be displayed on User Display Line 2 of the Process Display screen.For example, setting to “5” selects PowerFlex 4-Class drive Parameter 5 - [DC Bus Voltage] to be displayed.Default:5Minimum:1Maximum:65535Type:Read/Write06[Large Disp Param]Selects a desired drive parameter to be displayed on the Large Format User Display screen.For example, setting to “1” selects PowerFlex 4-Class drive Parameter 1 - [Output Freq] to be displayed. Setting to “0” enables the Scaled Reference to be displayed.Default:1Minimum:0Maximum:65535Type:Read/Write07[LCD Contrast]Sets the HIM LCD contrast level.Default:50%Minimum:0%Maximum:100%Type:Read/Write08[Reset HIM]1 (Reset):Resets the HIM.2 (Set Defaults):Resets HIM parameters to factory settings.This parameter returns to a value of “0” (Ready) after the reset function is complete.Default:0 = ReadyValues0 = Ready1 = Reset2 = Set DefaultsType:Read/Write09[Device Type]Selects the HIM device type. When set to “0” (Auto), the HIM is automatically configured as either a DSI Master or Slave depending on the presence of other peripheral devices.Default:0 = AutoValues0 = Auto1 = Slave2 = MasterType:Read/Write10[M/S Status]Displays the HIM active device type.Default:N/AValues1 = Slave2 = MasterType:Read Only11[HIM Ref Preset]0 (Zero Start):HIM Reference is always “0.0” at power on.1 (Host Output):HIM will assume the Host’s output feedback (bumpless transfer) and preset its Reference when the Reference is configured to be received on the RS-485 port. This can be verified by viewing Diagnostics/Device Status/Remote Freq Ref = 1.2 (Last HIM Ref):HIM will store the HIM Reference in EEPROM each time it is changed. HIM Reference is restored at power on.Default:0 = Zero StartValues0 = Zero Start1 = Host Output2 = Last HIM RefType:Read/Write NOTE: New settings to HIM parameters are implemented immediately. Resetting the HIM is not required for new values to take effect.12[Ref Scaling]Enables or disables scaling the Reference to a user-defined value. When Parameter 12 - [Ref Scaling] is set to “1” (Enabled), use HIM Parameters 13…22 to scale the Reference.Default:0 = DisabledValues:0 = Disabled1 = EnabledType:Read/Write13[Ref Max Value]Sets the user-defined value to be displayed when the drive is running at 60 Hz.Default:600Minimum:100Maximum:65535Type:Read/Write14[Ref Dec Position]Sets the number of digits to be displayed to the right of the decimal point for the Reference.Default:1Minimum:0Maximum:3Type:Read/Write1516171819202122[Ref Units Char 1][Ref Units Char 2][Ref Units Char 3][Ref Units Char 4][Ref Units Char 5][Ref Units Char 6][Ref Units Char 7][Ref Units Char 8]Selects up to 8 characters (from the ISO 8859-1 character set) to use for the Reference units on the Process Display.Parameters 15…22 can also be configured using the “Edit Ref Text” selection in the HIM Setup tab.Default:72(“H”)Default:122(“z”)Default:32(blank - no character)Default:32(blank - no character)Default:32(blank - no character)Default:32(blank - no character)Default:32(blank - no character)Default:32(blank - no character)Minimum:32Maximum:255Type:Read/Write23[Fault Dspy Type]Selects the type of display flash to be shown when a drive or peripheral fault is detected.Default:0 = Flash BkliteValues:0 = Flash Bklite1 = Flash NoneType:Read/Write24[Alarm Dspy Type]Selects the type of display flash to be shown when a drive alarm is detected.Default:1 = Flash NoneValues:0 = Flash Bklite1 = Flash NoneType:Read/WriteParameterNo.Name and DescriptionDetailswww.rockwellautomation.comAmericas: Rockwell Automation, 1201 South Second Street, Milwaukee, WI 53204-2496 USA, Tel: (1) 414.382.2000, Fax: (1) 414.382.4444Europe/Middle East/Africa: Rockwell Automation, Vorstlaan/Boulevard du Souverain 36, 1170 Brussels, Belgium, Tel: (32) 2 663 0600, Fax: (32) 2 663 0640Asia Pacific: Rockwell Automation, Level 14, Core F, Cyberport 3, 100 Cyberport Road, Hong Kong, Tel: (852) 2887 4788, Fax: (852) 2508 1846Power, Control and Information Solutions HeadquartersU.S. Allen-Bradley Drives Technical SupportTel: (1) 262.512.8176, Fax: (1) 262.512.2222, Email: support@drives.ra.rockwell.com, Online: www.ab.com/support/abdrivesPublication 22HIM-QR001F – September 2009Supersedes 22HIM-QR001E-EN-P – April 2005Copyright © 2009 Rockwell Automation, Inc. All rights reserved. Printed in USA.

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: PowerFlex 4-Class HIM (DSI) Quick Reference

评论

发表评论
< /4 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功