您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > Yokogawa Electric Corporation Personal Computer Link Ethernet

Yokogawa Electric Corporation Personal Computer Link Ethernet

  • 文哥
  • 19 人阅读
  • 0 人下载
  • 2019-02-20 11:28:28

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有19人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1Yokogawa Electric CorporationPersonal Computer Link Ethernet Driver1System Configuration.......................................................................................................32Selection of External Device..........................................................................................103Example of Communication Setting...............................................................................114Setup Items....................................................................................................................595Supported Device...........................................................................................................636Device Code and Address Code....................................................................................697Error Messages..............................................................................................................74Personal Computer Link Ethernet Driver GP-Pro EX Device/PLC Connection Manual2IntroductionThis manual describes how to connect the Display and the External Device (target PLC).In this manual, the connection procedure will be described by following the below sections:1System ConfigurationThis section shows the types of External Device which can be connected and SIO type."1 System Configuration" (page 3)2Selection of External DeviceSelect a model (series) of the External Device to be connected and connection method."2 Selection of External Device" (page 10)3Example of Communication SettingsThis section shows setting examples for communicating between the Display and the External Device."3 Example of Communication Setting" (page 11)4Setup ItemsThis section describes communication setup items on the Display.Set communication settings of the Display with GP-Pro Ex or in offline mode."4 Setup Items" (page 59)OperationPersonal Computer Link Ethernet Driver GP-Pro EX Device/PLC Connection Manual31System ConfigurationThe system configuration in the case when the External Device and the Display are connected is shown.SeriesCPULink I/FPort No.Communication MethodData Code SettingsSetting ExampleFA-M3F3SP25-2NF3SP28-3NF3SP35-5NF3SP38-6NF3SP53-4HF3SP58-6HF3LE01-5T *112289Ethernet(UDP)Binary*2Setting Example 1 (page 11)ASCII*3Setting Example 2 (page 13)Ethernet(TCP)Binary*2Setting Example 5 (page 19)ASCII*3Setting Example 6 (page 21)F3LE11-0T *112289Ethernet(UDP)Binary*2Setting Example 1 (page 11)ASCII*3Setting Example 2 (page 13)Ethernet(TCP)Binary*2Setting Example 5 (page 19)ASCII*3Setting Example 6 (page 21)12291Ethernet(UDP)Binary*3Setting Example 3 (page 15)ASCII*2Setting Example 4 (page 17)Ethernet(TCP)Binary*3Setting Example 7 (page 23)ASCII*2Setting Example 8 (page 25)Personal Computer Link Ethernet Driver GP-Pro EX Device/PLC Connection Manual4FA-M3F3SP21-0NF3SP28-3SF3SP38-6SF3SP53-4SF3SP58-6SF3SP59-7SF3LE01-5T *1F3LE01-0T *112289Ethernet(UDP)Binary*2Setting Example 1 (page 11)ASCII*3Setting Example 2 (page 13)Ethernet(TCP)Binary*2Setting Example 5 (page 19)ASCII*3Setting Example 6 (page 21)F3LE11-0T *1F3LE12-0T *112289Ethernet(UDP)Binary*2Setting Example 1 (page 11)ASCII*3Setting Example 2 (page 13)Ethernet(TCP)Binary*2Setting Example 5 (page 19)ASCII*3Setting Example 6 (page 21)12291Ethernet(UDP)Binary*3Setting Example 3 (page 15)ASCII*2Setting Example 4 (page 17)Ethernet(TCP)Binary*3Setting Example 7 (page 23)ASCII*2Setting Example 8 (page 25)F3SP22-0SF3LE01-0T *112289Ethernet(UDP)Binary*2Setting Example 1 (page 11)ASCII*3Setting Example 2 (page 13)Ethernet(TCP)Binary*2Setting Example 5 (page 19)ASCII*3Setting Example 6 (page 21)SeriesCPULink I/FPort No.Communication MethodData Code SettingsSetting ExamplePersonal Computer Link Ethernet Driver GP-Pro EX Device/PLC Connection Manual5FA-M3F3SP22-0SF3LE11-0T *1F3LE12-0T *112289Ethernet(UDP)Binary*2Setting Example 1 (page 11)ASCII*3Setting Example 2 (page 13)Ethernet(TCP)Binary*2Setting Example 5 (page 19)ASCII*3Setting Example 6 (page 21)12291Ethernet(UDP)Binary*3Setting Example 3 (page 15)ASCII*2Setting Example 4 (page 17)Ethernet(TCP)Binary*3Setting Example 7 (page 23)ASCII*2Setting Example 8 (page 25)F3SP66-4SF3SP67-6SEthernet I/F on CPU Unit12289Ethernet(UDP)BinarySetting Example 9 (page 27)ASCIISetting Example 10 (page 29)Ethernet(TCP)BinarySetting Example 11 (page 31)ASCIISetting Example 12 (page 33)12291Ethernet(UDP)BinarySetting Example 13 (page 35)ASCIISetting Example 14 (page 37)Ethernet(TCP)BinarySetting Example 15 (page 39)ASCIISetting Example 16 (page 41)F3LE01-0T *112289Ethernet(UDP)Binary*2Setting Example 1 (page 11)ASCII*3Setting Example 2 (page 13)Ethernet(TCP)Binary*2Setting Example 5 (page 19)ASCII*3Setting Example 6 (page 21)SeriesCPULink I/FPort No.Communication MethodData Code SettingsSetting Example

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: Yokogawa Electric Corporation Personal Computer Link Ethernet

评论

发表评论
< /74 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功