您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > TOSHIBA Corporation Computer Link Ethernet

TOSHIBA Corporation Computer Link Ethernet

  • 文哥
  • 29 人阅读
  • 0 人下载
  • 2019-02-20 11:28:24

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有29人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1TOSHIBA CorporationComputer Link Ethernet Driver1System Configuration.......................................................................................................32Selection of External Device............................................................................................63Example of Communication Setting.................................................................................74Setup Items....................................................................................................................165Supported Device...........................................................................................................206Device Code and Address Code....................................................................................267Error Messages..............................................................................................................30Computer Link Ethernet DriverGP-Pro EX Device/PLC Connection Manual2IntroductionThis manual describes how to connect the Display and the External Device (target PLC).In this manual, the connection procedure will be described by following the sections below:1System ConfigurationThis section shows the types of External Devices which can be connected and SIO type.�"1 System Configuration" (page 3)2Selection of External DeviceSelect the model (series) of the External Device to be connected and its connection method.�"2 Selection of External Device" (page 6)3Example of Communication SettingsThis section shows setting examples for communicating between the Display and the External Device.�"3 Example of Communication Setting" (page 7)4Setup ItemsThis section describes communication setup items on the Display.Set the communication settings of the Display with GP-Pro EX or in offline mode.�"4 Setup Items" (page 16)OperationComputer Link Ethernet DriverGP-Pro EX Device/PLC Connection Manual31System ConfigurationThe following shows the system configuration where the External Device of TOSHIBA Corporation and the Display are connected.�Connection Configuration[1:1 Connection]Series NameModel/CPULink I/FSIO TypeSetting ExampleT SeriesT2NPU-235NPU-245NEthernet (UDP)Setting Example 1 (page 7)T3HEN311Setting Example 2 (page 9)S2TEN611EN631EN651ASetting Example 4 (page 14)V SeriesModel2000S2PU22AS2PU32AS2PU72AS2PU72DS2PU82EN611EN621EB621EN631EN641EB641EN651AEN661FN661Ethernet (UDP)Setting Example 3 (page 11)Model3000S3PU21S3PU45AS3PU55AS3PU55BS3PU65AEN711EN721EN731EN741EN751EN761FN711•The length of the communication cable depends on the I/F link to be used. Please refer to the manual of the External Device for details.DisplayExternal deviceHUBComputer Link Ethernet DriverGP-Pro EX Device/PLC Connection Manual4[1:n Connection][[n:1 Connection][[n:m Connection]DisplayExternal DeviceMaximum 32 units for UDPHUBExternal DeviceExternal DeviceDisplayHUBExternal DeviceMaximum connecton unit *DisplayDisplay* For T Series, one External Device can connect to up to two Displays. For V Series, there is no limit to the number of Displays that can be connected to one External Device. Note that more Displays will result in increasing the communication load.DisplayHUBExternal DeviceDisplayExternal DeviceExternal DeviceDisplayMaximum 32 units for UDPMaximum connecton unit ** For T Series, one External Device can connect to up to two Displays. For V Series, there is no limit to the number of Displays that can be connected to one External Device. Note that more Displays will result in increasing the communication load.Computer Link Ethernet DriverGP-Pro EX Device/PLC Connection Manual5[When using the gateway function]Example)<Setting Example>To access the above External Device 2 with station No. 10, check [Use gateway function] in the [Device-Specific Settings] window and then configure the following settings.These settings provide access to External Device 2 via External Device 1.•The CPU available with External Device 1 is T3H (Firmware version 1.2 or later) only. For External Device 2 and 3, T3H or S2T only.•Channel Nos. are assigned in order from near the CPU.•Station Nos. can be set using the switch on the TOSLINE module (setting range: 1 to 64).ItemSettingChannel No.1Station No.10DisplayHUBPower unitCPUEN311Power unitPower unitExternalDevice 1ExternalDevice 2ExternalDevice 3Station No.=10Station No.=20Channel No.=2Channel No.=1SN32*SN32*CPUSN32*CPUSN32*

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: TOSHIBA Corporation Computer Link Ethernet

评论

发表评论
< /30 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功