您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > Sharp Manufacturing Systems Corporation JW Series Computer Link Ethernet

Sharp Manufacturing Systems Corporation JW Series Computer Link Ethernet

  • 文哥
  • 27 人阅读
  • 0 人下载
  • 2019-02-20 11:28:20

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有27人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1Sharp Manufacturing Systems CorporationJW Series Computer Link Ethernet Driver1System Configuration.......................................................................................................32Selection of External Device............................................................................................53Example of Communication Setting.................................................................................64Setup Items....................................................................................................................225Supported Device...........................................................................................................266Device Code and Address Code....................................................................................347Error Messages..............................................................................................................42JW Series Computer Link Ethernet DriverGP-Pro EX Device/PLC Connection Manual2IntroductionThis manual describes how to connect the Display and the External Device (target PLC).In this manual, the connection procedure will be described by following the sections below:1System ConfigurationThis section shows the types of External Devices which can be connected and SIO type."1 System Configuration" (page 3)2Selection of External DeviceSelect a model (series) of the External Device to be connected and connection method."2 Selection of External Device" (page 5)3Example of Communication SettingsThis section shows setting examples for communicating between the Display and the External Device."3 Example of Communication Setting" (page 6)4Setup ItemsThis section describes communication setup items on the Display.Set communication settings of the Display with GP-Pro EX or in offline mode."4 Setup Items" (page 22)OperationJW Series Computer Link Ethernet DriverGP-Pro EX Device/PLC Connection Manual31System ConfigurationThe following shows the system configuration where the External Device of SHARP MS Corporation and the Display are connected.Connection Configuration[1:1 Connection]Series NameCPULink I/FSIO TypeSetting ExampleJW300*1*1Available with the Ethernet units compatible with JW300. "300" is labeled on the front of JW300-compatible units. For more information, contact the manufacturer of the External Device.JW-311CUJW-312CUJW-25TCMJW-255CMEthernet (UDP)Setting Example 1 (page 6)Ethernet (TCP)Setting Example 2 (page 8)JW-321CUJW-322CUEthernet (UDP)Setting Example 3 (page 10)Ethernet (TCP)Setting Example 4 (page 12)JW-331CUJW-332CUJW-341CUJW-342CUJW-352CUJW-362CUEthernet (UDP)Setting Example 5 (page 14)Ethernet (TCP)Setting Example 6 (page 16)JW30HJW-31CUH1JW-32CUH1JW-32CUM1JW-32CUM2JW-33CUH1JW-33CUH2JW-33CUH3JW-25TCMJW-255CMEthernet (UDP)Setting Example 7 (page 18)Ethernet (TCP)Setting Example 8 (page 20)DisplayExternal DeviceHUBEthernetUnitJW Series Computer Link Ethernet DriverGP-Pro EX Device/PLC Connection Manual4[1:n Connection][n:1 Connection][n:m Connection]DisplayExternal DeviceHUBEthernetunitExternal DeviceEthernetunit*1 You can connect up to 32 units of External Device for UDP, and 16 units of External Device for TCP at the same time.Maximum connection unit *1DisplayHUBExternal DeviceEthernetunitMaximum 8 unitsDisplayDisplayHUBExternal DeviceEthernetunitDisplayExternal DeviceEthernetunitExternal DeviceEthernetunitDisplayMaximum 8 units*1 You can connect up to 32 units of External Device for UDP, and 16 units of External Device for TCP at the same time.Maximum connection unit *1JW Series Computer Link Ethernet DriverGP-Pro EX Device/PLC Connection Manual52Selection of External DeviceSelect the External Device to be connected to the Display.Setup ItemsSetup DescriptionMakerSelect the maker of the External Device to be connected. Select "SHARP MS Corporation".DriverSelect a model (series) of the External Device to be connected and connection method. Select "JW Series Computer Link Ethernet".Check the External Device which can be connected in "JW Series Computer Link Ethernet" in system configuration."1 System Configuration" (page 3)Use System AreaCheck this option to synchronize the system data area of the Display and the device (memory) of the External Device. When synchronized, you can use the External Device's ladder program to switch the display or display the window on the Display.Cf.GP-Pro EX Reference Manual "LS Area (Direct Access Method Area)"This feature can also be set in GP-Pro EX or in the Display's offline mode.Cf.GP-Pro EX Reference Manual "System Settings [Display Unit] - [System Area] Settings Guide"Cf.Maintenance/Troubleshooting Guide "Main Unit - System Area Settings"PortSelect the port of the Display to be connected to the External Device from "Ethernet (UDP)" and "Ethernet (TCP)".

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: Sharp Manufacturing Systems Corporation JW Series Computer Link Ethernet

评论

发表评论
< /42 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功