您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > Rockwell Automation, Inc. EtherNetIP

Rockwell Automation, Inc. EtherNetIP

  • 文哥
  • 13 人阅读
  • 0 人下载
  • 2019-02-20 11:28:13

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有13人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1Rockwell Automation, Inc.EtherNet/IP Driver1System Configuration.......................................................................................................32External Device Selection................................................................................................83Communication Settings..................................................................................................94Setup Items....................................................................................................................315Supported Devices.........................................................................................................366Device Code and Address Code....................................................................................687Error Messages..............................................................................................................69EtherNet/IP Driver GP-Pro EX Device/PLC Connection Manual2IntroductionThis manual describes how to connect the Display and the External Device (target PLC).In this manual, the connection procedure is described in the sections identified below:1System ConfigurationThis section lists the types of External Devices that you can connect."1 System Configuration" (page 3)2External Device SelectionSelect a model (series) of the External Device to be connected and a connection method."2 External Device Selection" (page 8)3Communication SettingsThis section shows setting examples for communicating between the Display and the External Device."3 Communication Settings" (page 9)4Setup ItemsThis section describes communication setup items on the Display.Set communication settings of the Display with GP-Pro EX or in offline mode."4 Setup Items" (page 31)OperationEtherNet/IP Driver GP-Pro EX Device/PLC Connection Manual31System ConfigurationThe system configuration in the case when the External Device and the Display are connected is shown.Series NameCPULink I/FCommunication MethodSetting ExampleSLC500SLC 5/05CPU Direct (channel1)*1Ethernet (TCP)Setting Example 1 (page 9)SLC 5/03SLC 5/04SLC 5/051761-NET-ENISetting Example 2 (page 11)PLC-5All CPUs that support the link I/F on the right1761-NET-ENISetting Example 3 (page 13)ControlLogixAll CPUs that support the link I/F on the right1756-ENET/B1756-ENET1756-ENBT1756-EN2T/ASetting Example 4 (page 15)1761-NET-ENISetting Example 5 (page 17)ControlLogixNative*2All CPUs that support the link I/F on the right1756-ENET/B1756-ENET1756-ENBT1756-EN2T/ASetting Example 9 (page 25)1761-NET-ENI*3Setting Example 10 (page 27)MicroLogixMicroLogix 1000MicroLogix 1100MicroLogix 1200MicroLogix 15001761-NET-ENISetting Example 6 (page 19)MicroLogix 1100CPU Direct (channel1)Setting Example 7 (page 21)CompactLogixAll CPUs that support the link I/F on the right1761-NET-ENISetting Example 5 (page 17)All CPUs that have Built-in EtherNet/IP portCPU DirectSetting Example 8 (page 23)CompactLogixNative*2All CPUs that support the link I/F on the right1761-NET-ENI*3Setting Example 10 (page 27)All CPUs that have Built-in EtherNet/IP port*4CPU DirectSetting Example 11 (page 29)EtherNet/IP Driver GP-Pro EX Device/PLC Connection Manual4FlexLogixAll CPUs that support the link I/F on the right1788-ENBT/AEthernet (TCP)Setting Example 4 (page 15)1761-NET-ENISetting Example 5 (page 17)FlexLogixNative*2All CPUs that support the link I/F on the right1788-ENBT/ASetting Example 9 (page 25)*1Rockwell EtherNet/IP driver for Display uses the CIP protocol. Old revision of SLC 5/05 CPU does not support it. Upgrade CPU Series A to the firmware revision of OS501, FRN5 or later. CPU Series B and C support the CIP protocol.*2Select Control/Compact/Flex Logix Native when using Native tag names on External Devices.*3To use the 1761-NET-ENI with the "Control/Compact/Flex Logix Series Native", the module must be Series B or later.*4Refer to the following for the CPU that generates a controller tag of Embedded I/O when the L5K file is imported."  Data Type Defined Module List" (page 51)•Projects created with the Ethernet/IP Driver Version 1.12.06 or later can be used with applications (GP-Pro EX and Pro-Server EX) that have a driver of that version or greater installed.A project cannot be used with applications that use an earlier driver version than that used in the project.•If the driver version is older than V1.12.06, download the latest driver from the support site, "Otasuke Pro!"Pro-face Service & Support "Otasuke Pro!"http://www.pro-face.com/otasuke/•When using an EtherNet/IP Driver with Version V1.14.12 or later, and a project is opened in an application with an earlier driver version installed, the configuration will be changed as follows.•A tag data block with the tag data name “NoData” and the controller tag “DINT” will be created.•The addresses set on screens and other locations are changed to "Undefined".•When the project is saved, changed data overwrites the previous data.•If a project was created with an earlier version of the driver, save it in the application with the newer driver installed before transferring to the Display.Series NameCPULink I/FCommunication MethodSetting ExampleEtherNet/IP Driver GP-Pro EX Device/PLC Connection Manual5•The device storage order of data varies depending on the device/PLC. Change the Text Data Mode to match the device order same as a device/PLC.To change the Text Data Mode, click [Change] in [Text Data Mode] to display a dialog box.

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: Rockwell Automation, Inc. EtherNetIP

评论

发表评论
< /70 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功