您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > Panasonic Industrial Devices Co., Ltd. FP Series Computer Link SIO

Panasonic Industrial Devices Co., Ltd. FP Series Computer Link SIO

  • 文哥
  • 11 人阅读
  • 0 人下载
  • 2019-02-20 11:28:05

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有11人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1Panasonic Industrial Devices SUNX Co., Ltd.FP Series Computer Link SIO Driver1System Configuration.......................................................................................................32Selection of External Device............................................................................................93Example of Communication Setting...............................................................................104Setup Items....................................................................................................................435Cable Diagram...............................................................................................................486Supported Device.........................................................................................................1307Device Code and Address Code..................................................................................1328Error Messages............................................................................................................134FP Series Computer Link SIO Driver GP-Pro EX Device/PLC Connection Manual2IntroductionThis manual describes how to connect the Display and the External Device (target PLC).In this manual, the connection procedure will be described by following the below sections:1System ConfigurationThis section shows the types of External Devices which can be connected and SIO type.�"1 System Configuration" (page 3)2Selection of External DeviceSelect a model (series) of the External Device to be connected and connection method.�"2 Selection of External Device" (page 9)3Example of Communication SettingsThis section shows setting examples for communicating between the Display and the External Device.�"3 Example of Communication Setting" (page 10)4Setup ItemsThis section describes communication setup items on the Display.Set communication settings of the Display with GP-Pro Ex or in offline mode.�"4 Setup Items" (page 43)5Cable DiagramThis section shows cables and adapters for connecting the Display and the External Device.�"5 Cable Diagram" (page 48)OperationFP Series Computer Link SIO Driver GP-Pro EX Device/PLC Connection Manual31System ConfigurationThe system configuration in the case when the External Device of Panasonic Industrial Devices SUNX Co., Ltd. and the Display are connected is shown.SeriesCPULink I/FSIO TypeSetting ExampleCable DiagramFPFPΣTool port of the control unitRS232CSetting Example 1 (page 10)Cable Diagram 8 (page 84)AFPG801Cable Diagram 1 (page 48)AFPG802Cable Diagram 2 (page 50)AFPG806Cable Diagram 4 (page 66)AFPG803RS422/485 (2wire)Setting Example 2 (page 12)Cable Diagram 3 (page 53)AFPG806Cable Diagram 5 (page 68)FP0Tool port of the control unitRS232CSetting Example 3 (page 14)Cable Diagram 8 (page 84)RS232C port of the control unit*1RS232CCable Diagram 6 (page 81)FP1Tool port of the control unitRS232CSetting Example 4 (page 16)Cable Diagram 9 (page 85)RS232C port of the control unit*2RS232CCable Diagram 7 (page 83)FP-MTool port of the control unitRS232CSetting Example 5 (page 18)Cable Diagram 8 (page 84)RS232C port of the control unit*3RS232CCable Diagram 7 (page 83)FP Series Computer Link SIO Driver GP-Pro EX Device/PLC Connection Manual4FPFP2 FP2SHTool port of the control unitRS232CSetting Example 6 (page 20)Cable Diagram 8 (page 84)RS232C port of the control unitRS232CCable Diagram 7 (page 83)AFP2462RS232CCable Diagram 7 (page 83)AFP2465*4AFP2803RS232CSetting Example 6 (page 20)Cable Diagram 7 (page 83)AFP2804RS422/485 (4wire)Setting Example 7 (page 23)Cable Diagram 11 (page 87)AFP2805RS422/485 (2wire)Setting Example 8 (page 25)Cable Diagram 3 (page 53)FP3Tool port of the control unitRS232CSetting Example 9 (page 27)Cable Diagram 10 (page 86)AFP3462RS232CCable Diagram 7 (page 83)FP-eTool port of the control unitRS232CSetting Example 10 (page 29)Cable Diagram 8 (page 84)AFPE224300RS232CCable Diagram 12 (page 92)AFPE224305AFPE214325AFPE224302RS422/485 (2wire)Setting Example 11 (page 31)Cable Diagram 13 (page 94)AFPE214322FP10SRS232C port of the control unitRS232CSetting Example 12 (page 33)Cable Diagram 7 (page 83)AFP3462RS232CCable Diagram 7 (page 83)SeriesCPULink I/FSIO TypeSetting ExampleCable DiagramFP Series Computer Link SIO Driver GP-Pro EX Device/PLC Connection Manual5FPFP10SHTool port of the control unitRS232CSetting Example 12 (page 33)Cable Diagram 14 (page 107)RS232C port of the control unitRS232CCable Diagram 7 (page 83)AFP3462RS232CCable Diagram 7 (page 83)AFP7CPS41E*5AFP7CPS31E*5AFP7CPS31*5AFP7CPS41ES*5AFP7CPS31ES*5AFP7CPS31S*5AFP7CPS21*5COM0 portRS232CSetting Example 13 (page 37)Cable Diagram 15 (page 108)AFP7CCS1AFP7CCS2 (3wire setting)AFP7CCS1M1AFP7CCS2 (5wire setting)RS232CCable Diagram 16 (page 110)AFP7CCM1RS422/485 (4wire)Setting Example 14 (page 39)Cable Diagram 17 (page 112)AFP7CCM2AFP7CCM1RS422/485 (2wire)Setting Example 15 (page 41)Cable Diagram 18 (page 117)AFP7CCM2AFP7CCS1M1*1Only FP0 (C10CRM/C10CRS/C14CRM/C14CRS/C16CT/C16CP/C32CT/C32CP) is equipped with the RS232C port. Other models are not.*2Only FP1 (C24/C40/C56/C72) is equipped with the RS232C port. Other models are not.*3Only FP-M (C20R/C20T/C32T) is equipped with the RS232C port. Other models are not.*4AFP2465 is the multicommunication unit of FP2/FP2SH. AFP2803, AFP2084 and AFP2085 are the communication blocks attached to AFP2465.*5Using FP7, including the CPU's COM port, the number of channels you can connect with the display unit is up to 3 channels.•When the time of GP4000 series is automatically updated in [Clock Update Settings] of GP-Pro EX, there are some restrictions as shown below. For details on [Clock Update Settings], refer to GP-Pro EX Reference Manual.•FP0 and FP-e does not support automatic update of the time. Specify [Customize] in [Clock Update Settings].•When the time is automatically updated in FP2, any of the extension memory unit FP2-EM1, FP2-EM2 or FP2-EM3 is required.•When the time is automatically updated in FP3, any of the AFP3210C-F, AFP3211C-F, AFP3212C-F or AFP3220C-F is required.SeriesCPULink I/FSIO TypeSetting ExampleCable Diagram

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: Panasonic Industrial Devices Co., Ltd. FP Series Computer Link SIO

评论

发表评论
< /134 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功