您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > ODVA EtherNetIP Explicit Messaging Driver

ODVA EtherNetIP Explicit Messaging Driver

  • 文哥
  • 13 人阅读
  • 0 人下载
  • 2019-02-20 11:28:00

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有13人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1ODVA (Open DeviceNet Vendor Association, Inc.)EtherNet/IP Explicit Messaging Driver1System Configuration.......................................................................................................32External Device Selection................................................................................................63Communication Settings..................................................................................................74Setup Items......................................................................................................................95Supported Device Addresses.........................................................................................176Device Code and Address Code....................................................................................227Error Messages..............................................................................................................26EtherNet/IP Explicit Messaging DriverGP-Pro EX Device/PLC Connection Manual2IntroductionThis manual describes how to connect the Display and the External Device (target PLC).In this manual, the connection procedure is described in the sections identified below:1System ConfigurationThis section lists the types of External Devices and SIO that you can connect."1 System Configuration" (page 3)2External Device SelectionSelect the model (series) of the External Device and its connection method."2 External Device Selection" (page 6)3Communication SettingsThis section shows setting examples for communicating between the Display and the External Device."3 Communication Settings" (page 7)4Setup ItemsThis section describes communication setup items on the Display.Set the Display's communication settings in GP Pro-EX or in offline mode."4 Setup Items" (page 9)OperationEtherNet/IP Explicit Messaging DriverGP-Pro EX Device/PLC Connection Manual31System ConfigurationThe following table lists system configurations for connecting External Devices and the Display.This driver is not certified by ODVA. Check the following when working with the driver.•Implicit MessagingThe equipment listed below has been tested and confirmed to operate. For the latest list, refer to our home page (http://www.pro-face.com/trans/en/manual/1056.html). If you use equipment that is not listed, fully test the equipment in an operation environment.•Explicit MessagingThe service codes and data sizes you can use are as follows.•Service code: Get_Attribute_Single, Set_Attribute_Single•Data size: 16-Bit, 32-BitUse Custom Explicit Message to implement different service codes or data sizes.DriverCPULink I/FSIO TypeSetting ExampleEtherNet/IPExplicit message serverEthernet port on the External DeviceEthernet (TCP)Setting Example 1 (page 7)•The display unit operates as the Originator.CPULink I/FWAGO CorporationModel: 750-352Model: 750-402Model: 750-467Model: 750-504Model: 750-550Phoenix ContactModel: IL EIP BK DI8 DO4 2TX-PACEthernet/IP Bus Coupler’s Ethernet/IP connectorSMCModel: EX600-8EN1SI unit’s BUS connectorApplied Motion ProductsModel: ST10-IP-EE-Schneider ElectricModel: LMDCE571-EtherNet/IP Explicit Messaging DriverGP-Pro EX Device/PLC Connection Manual4Connection Configuration•1:n Connection•n:1 Connection•n:m Connection*1When 33 or more External Devices are connected, it is necessary to check [Increase allowable number of Devices/PLCs]."4.1 Setup Items in GP-Pro EX" (page 9)*2The maximum number of connectable units varies depending on the External Device. Refer to your External Device manual for details.HUBDisplayExternalDeviceExternalDeviceExternalDeviceMaximum number of connections: 64 units *1HUBDisplayExternalDeviceMaximum number of connections: n unit(s) *2DisplayDisplayHUBDisplayExternalDeviceMaximum number of connections: n unit(s) *2DisplayDisplayExternalDeviceExternalDeviceEtherNet/IP Explicit Messaging DriverGP-Pro EX Device/PLC Connection Manual5•Increasing the number of External Devices increases the communication load. If you use Implicit Messaging and the communication load is too high, you may not be able to get data. When that happens, to reduce the communication load, either increase the length of the Requested Packet Interval (RPI) or reduce the number of connected devices.Posted on the "Otasuke Pro!" (http://www.pro-face.com/trans/en/manual/1001.html) support site's download page for the ODVA EtherNet/IP Explicit Messaging driver is the configuration that worked in our test environment.•For Implicit Messaging multicast communication, use communication speeds of 100BASE-TX or faster.

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: ODVA EtherNetIP Explicit Messaging Driver

评论

发表评论
< /28 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功