您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > Mitsubishi Electric Corporation QQnA Series Ethernet

Mitsubishi Electric Corporation QQnA Series Ethernet

  • 文哥
  • 11 人阅读
  • 0 人下载
  • 2019-02-20 11:27:58

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有11人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1Mitsubishi Electric Corporation Q/QnA SeriesEthernet Driver1System Configuration.......................................................................................................32Selection of External Device............................................................................................83Example of Communication Setting.................................................................................94Setup Items....................................................................................................................495Supported Device...........................................................................................................576Device Code and Address Code....................................................................................687Error Messages..............................................................................................................74Q/QnA Series Ethernet Driver GP-Pro EX Device/PLC Connection Manual2IntroductionThis manual describes how to connect the display and the External Device (target PLC).In this manual, the connection procedure will be described by following the below sections:1System ConfigurationThis section shows the types of External Device and SIO type."1 System Configuration" (page 3)2Selection of External DeviceSelect a model (series) of External Device to be connected and connection method."2 Selection of External Device" (page 8)3Example of Communication SettingsThis section shows setting examples for communicating between the display and the External Device."3 Example of Communication Setting" (page 9)4Setup ItemsThis section describes communication setup items on the display device.Set communication settings of Display with GP-Pro Ex or in offline mode."4 Setup Items" (page 49)OperationQ/QnA Series Ethernet Driver GP-Pro EX Device/PLC Connection Manual31System ConfigurationThe system configuration in the case when the External Device and the Display are connected is shown.SeriesCPULink I/FSIO TypeSetting ExampleMELSEC Q SeriesQ00CPUQ00JCPUQ01CPUQ02CPUQ02HCPUQ06HCPUQ12HCPUQ25HCPUQ03UDECPUQ04UDEHCPUQ06UDEHCPUQ13UDEHCPUQ26UDEHCPUQ02UCPUQ03UDCPUQ04UDHCPUQ06UDHCPUQ13UDHCPUQ26UDHCPUQ03UDVCPUQ04UDVCPUQ06UDVCPUQ13UDVCPUQ26UDVCPUQJ71E71Ethernet (UDP)Setting Example 1 (page 9)Ethernet (TCP)Setting Example 2 (page 14)QJ71E71-B2Ethernet (UDP)Setting Example 1 (page 9)Ethernet (TCP)Setting Example 2 (page 14)QJ71E71-B5Ethernet (UDP)Setting Example 1 (page 9)Ethernet (TCP)Setting Example 2 (page 14)QJ71E71-100Ethernet (UDP)Setting Example 1 (page 9)Ethernet (TCP)Setting Example 2 (page 14)MELSEC QnA SeriesQ2ACPUQ2ACPU-S1Q3ACPUQ4ACPUQ4ARCPUAJ71QE71Ethernet (UDP)Setting Example 3 (page 18)Ethernet (TCP)Setting Example 4 (page 22)AJ71QE71-B5Ethernet (UDP)Setting Example 3 (page 18)Ethernet (TCP)Setting Example 4 (page 22)Q2ASCPUQ2ASHCPUQ2ASCPU-S1Q2ASHCPU-S1A1SJ71QE71-B2Ethernet (UDP)Setting Example 3 (page 18)Ethernet (TCP)Setting Example 4 (page 22)A1SJ71QE71-B5Ethernet (UDP)Setting Example 3 (page 18)Ethernet (TCP)Setting Example 4 (page 22)Q/QnA Series Ethernet Driver GP-Pro EX Device/PLC Connection Manual4MELSEC L SeriesL02CPUL26CPU-BTEthernet port on CPU unitEthernet (UDP)Setting Example 5 (page 25)Ethernet (TCP)Setting Example 6 (page 28)MELSEC iQ-R SeriesR04CPUR04ENCPUR08CPUR08ENCPUR16CPUR16ENCPUR32CPUR32ENCPUR120CPUR120ENCPUEthernet port on CPUEthernet (UDP)Setting Example 7 (page 31)Ethernet (TCP)Setting Example 8 (page 34)RJ71EN71Ethernet (UDP)Setting Example 9 (page 37)Ethernet (TCP)Setting Example 10 (page 40)MELSEC iQ-F SeriesFX5UCPUFX5UCCPUEthernet port on CPUEthernet (UDP)Setting Example 11 (page 43)Ethernet (TCP)Setting Example 12 (page 46)•When you open the project file (which has been created with the Ver.1.12.04 or earlier Q/QnA series Ethernet driver) with GP-Pro EX where Ver.1.12.05 or later driver is installed, the [Multiple CPU system] checkbox in the [Basic] tab is checked. Specify [Multiple CPU system] according to the environment you use."  Device Setting" (page 50)•You can confirm the driver version using GP-Pro EX as follows:From [System Setting window] in the workspace, select [Peripheral List] to display the version.•The time of GP4000 series can be automatically updated in [Clock Update Settings] of GP-Pro EX, if you set the External Device bit address SM213 to ON.For details on [Clock Update Settings], refer to GP-Pro EX Reference Manual.SeriesCPULink I/FSIO TypeSetting ExampleQ/QnA Series Ethernet Driver GP-Pro EX Device/PLC Connection Manual5Connection Configuration•1:1 Connection•1:n Connection (when access station is source station)•1:n Connection (access beyond network)•In case of communication via network, please set larger value than the response monitoring time of the relay station for timeout settings.•When the relay station is iQ-R series, use units with firmware version 9 or later.•The iQ-F series cannot be used as a relay station.•Available devices and address ranges for an External Device that uses the network to communicate are limited to the devices and address ranges of the relay station.

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: Mitsubishi Electric Corporation QQnA Series Ethernet

评论

发表评论
< /74 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功