您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > Mitsubishi Electric Corporation iQ-RF Ethernet (SLMP Client)

Mitsubishi Electric Corporation iQ-RF Ethernet (SLMP Client)

  • 文哥
  • 15 人阅读
  • 0 人下载
  • 2019-02-20 11:27:55

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有15人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1Mitsubishi Electric Corporation iQ-R/F Ethernet (SLMP Client) Driver1System Configuration.......................................................................................................32External Device Selection................................................................................................73Communication Settings..................................................................................................84Setup Items....................................................................................................................265Supported Devices.........................................................................................................326Device Code and Address Code....................................................................................437Error Messages..............................................................................................................48iQ-R/F Ethernet (SLMP Client) DriverGP-Pro EX Connection Manual2IntroductionThis manual describes how to connect the Display and the External Device (target PLC).In this manual, the connection procedure will be described in the sections identified below:1System ConfigurationThis section lists the types of External Devices and SIO that you can connect."1 System Configuration" (page 3)2External Device SelectionSelect a model (series) of the External Device and its connection method."2 External Device Selection" (page 7)3Communication SettingsThis section shows setting examples for communicating between the Display and the External Device."3 Communication Settings" (page 8)4Setup ItemsThis section describes communication setup items on the Display. Set the Display’s communication settings in GP Pro-EX or in offline mode."4 Setup Items" (page 26)OperationiQ-R/F Ethernet (SLMP Client) Driver GP-Pro EX Connection Manual31System ConfigurationThe system configuration in the case when the External Device of Mitsubishi Electric Corporation and the Display are connected is shown.Connection Configuration•1:1 Connection•1:n ConnectionSeriesCPULink I/FSIO TypeSetting ExampleiQ-R SeriesR04CPUR08CPUR16CPUR32CPUR120CPUR04ENCPUR08ENCPUR16ENCPUR32ENCPUR120ENCPUEthernet Port on CPU UnitEthernet (UDP)Setting Example 1 (page 8)Ethernet (TCP)Setting Example 2 (page 11)RJ71EN71Ethernet (UDP)Setting Example 3 (page 14)Ethernet (TCP)Setting Example 4 (page 17)iQ-F SeriesFX5UCPUFX5UCCPUEthernet Port on CPU UnitEthernet (UDP)Setting Example 5 (page 20)Ethernet (TCP)Setting Example 6 (page 23)•The maximum number of External Devices you can connect is as follows.TCP/IP connection: 16UDP/IP connection: 32iQ-R/F Ethernet (SLMP Client) DriverGP-Pro EX Connection Manual4•1:n Connection (access outside the network to relay the iQ-R series)•When communication over the network, set the timeout to a value greater than the relay station's response monitoring time.•The maximum number of External Devices you can connect is as follows. TCP/IP connection: up to 16 UDP/IP connection: up to 32iQ-R/F Ethernet (SLMP Client) Driver GP-Pro EX Connection Manual5Setting examples for access outside the network are shown below. Check the details of the setup items in "Setup Items""4 Setup Items" (page 26)External Device to AccessPort No.Station No.Network No.PC No.Request destination moduleI/O No.Request destination moduleStation No.External Device (1)10255025510230External Device (11)102652610230External Device (22)10275383215

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: Mitsubishi Electric Corporation iQ-RF Ethernet (SLMP Client)

评论

发表评论
< /48 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功