您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > JTEKT CorporationTOYOPUC CMP-LINK Ethernet

JTEKT CorporationTOYOPUC CMP-LINK Ethernet

  • 文哥
  • 11 人阅读
  • 0 人下载
  • 2019-02-20 11:27:47

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有11人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1JTEKT CorporationTOYOPUC CMP-LINK Ethernet Driver1System Configuration.......................................................................................................32Selection of External Device............................................................................................63Example of Communication Setting.................................................................................74Setup Items....................................................................................................................405Supported Device...........................................................................................................446Device Code and Address Code....................................................................................507Error Messages..............................................................................................................54TOYOPUC CMP-LINK Ethernet DriverGP-Pro EX Device/PLC Connection Manual2IntroductionThis manual describes how to connect the Display and the External Device (target PLC).In this manual, the connection procedure will be described by following the below sections:1System ConfigurationThis section shows the types of External Devices which can be connected and SIO type."1 System Configuration" (page 3)2Selection of External DeviceSelect a model (series) of the External Device to be connected and connection method."2 Selection of External Device" (page 6)3Example of Communication SettingsThis section shows setting examples for communicating between the Display and the External Device."3 Example of Communication Setting" (page 7)4Setup ItemsThis section describes communication setup items on the Display.Set communication settings of the Display with GP-Pro EX or in offline mode."4 Setup Items" (page 40)OperationTOYOPUC CMP-LINK Ethernet DriverGP-Pro EX Device/PLC Connection Manual31System ConfigurationThe system configuration in the case when the External Device of JTEKT Corporation and the Display are connected is shown.Connection Configuration•1:1 ConnectionSeriesCPULink I/FSIO TypeProtocolOpen MethodSetting ExampleTOYOPUC-PC3PC3PC3JPC3JDPC3JGEthernet port of THU-5296*1*1In TCP connection, you can connect max 8 units of the Display to 1 External Device.Ethernet(UDP)UDPSetting Example 1 (page 7)Ethernet(TCP)Target unspecified passiveSetting Example 2 (page 10)Target specifiedpassiveSetting Example 3 (page 13)Ethernet port of THU-5781*1Ethernet(UDP)UDPSetting Example 4 (page 16)Ethernet(TCP)Target unspecified passiveSetting Example 5 (page 22)Target specifiedpassiveSetting Example 6 (page 28)TOYOPUC-PC10GPC10GL1 Port on CPU UnitL2 Port on CPU UnitEthernet(UDP)UDPSetting Example 7 (page 34)Ethernet(TCP)Target unspecified passiveSetting Example 8 (page 36)Target specifiedpassiveSetting Example 9 (page 38)HUBDisplayExternal DeviceTOYOPUC CMP-LINK Ethernet DriverGP-Pro EX Device/PLC Connection Manual4•1:n Connection•n:1 Connection•n:m Connection*1The maximum number of Displays varies depending on the External Device series and the settings.•When TOYOPUC-PC3 is used, up to 8 Displays can be connected.•When "Ethernet" is specified for L1/L2 port settings on the CPU unit in TOYOPUC-PC10G, up to 8 Displays can be connected.•When "Ethernet (32 ports)" is specified for L1/L2 port settings on the CPU unit in TOYOPUC-PC10G, up to 32 Displays can be connected."Ethernet (32 ports)" can be specified only when the CPU version is V.3.00 or later.*2For UDP and TCP connections, up to 32 and 16 External Devices can be connected respectively. HUBDisplayExternal DeviceExternal DeviceThe max number of External Device: n *2HUBDisplayExternal DeviceThe max number of Display: n *1DisplayHUBDisplayExternal DeviceThe max number of Display: n *1DisplayExternal DeviceThe max number of External Device: n *2TOYOPUC CMP-LINK Ethernet DriverGP-Pro EX Device/PLC Connection Manual5•FL-NET ConnectionYou can use this driver to access up to 4 layers of External Device connected to FL-NET.In the [Individual Device Settings] dialog box, in hierarchical order, set up the program number / link number of External Device that act as relays, and the destination External Device's node number.Example [Individual Device Settings] with the following network structure.Set up each connected piece of External Device (such as A1 and X1 shown in the figure) using the ladder software PCwin. Display the [Link parameter setup] dialog box and set up the program number / link number and node number of the port to connect to FL-NET.•Network Structure•Contents of [Individual Device Settings]External Device to accessNo. of LayersLayerProgram No.Link No.Relay / Destination(Node No.)X122125Y23212531630Z1421253162043410HUBFL-NET (Layer 2)FL-NET (Layer 4)FL-NET (Layer 3)X1Y1Y2Z1A1EthernetProgram No.: P1Link No.: 2Node No.: 5Program No.: P1Link No.: 6Program No.: P3Link No.: 4Node No.: 30Node No.: 20Node No.: 10

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: JTEKT CorporationTOYOPUC CMP-LINK Ethernet

评论

发表评论
< /54 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功