您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > LS Industrial Systems Co., Ltd. XGTXGB Series FEnet

LS Industrial Systems Co., Ltd. XGTXGB Series FEnet

  • 文哥
  • 17 人阅读
  • 0 人下载
  • 2019-02-20 11:27:45

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有17人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1LS Industrial Systems Co., Ltd.XGT/XGB Series FEnet Driver1System Configuration.......................................................................................................32Selection of External Device............................................................................................53Example of Communication Setting.................................................................................64Setup Items....................................................................................................................185Supported Device...........................................................................................................226Device Code and Address Code....................................................................................257Error Messages..............................................................................................................27XGT/XGB Series FEnet Driver GP-Pro EX Device/PLC Connection Manual2IntroductionThis manual describes how to connect the Display and the External Device (target PLC).In this manual, the connection procedure will be described by following the below sections:1System ConfigurationThis section shows the types of External Devices which can be connected and SIO type."1 System Configuration" (page 3)2Selection of External DeviceSelect a model (series) of the External Device to be connected and connection method. "2 Selection of External Device" (page 5)3Example of Communication SettingsThis section shows setting examples for communicating between the Display and the External Device. "3 Example of Communication Setting" (page 6)4Setup ItemsThis section describes communication setup items on the Display.Set communication settings of the Display with GP-Pro EX or in offline mode."4 Setup Items" (page 18)OperationXGT/XGB Series FEnet Driver GP-Pro EX Device/PLC Connection Manual31System ConfigurationThe system configuration in the case when the External Device of LS Industrial Systems Co., Ltd. and the Display are connected is shown.Connection Configuration•1:1 ConnectionSeriesCPULink I/FInterfaceSetting ExampleXGTXGK-CPUUXGK-CPUEXGK-CPUSXGK-CPUAXGK-CPUHXGK-CPUUNXGK-CPUHNXGK-CPUSNXGL-EFMTEthernet (UDP, TCP)Setting Example 1 (page 6)XGK-CPUUNXGK-CPUHNXGK-CPUSNPort on CPU unitEthernet ( TCP)Setting Example 6 (page 16)XGI-CPUU/DXGI-CPUUXGI-CPUHXGI-CPUSXGI-CPUEXGL-EFMTEthernet (UDP, TCP)Setting Example 2 (page 8)XGR-CPUH/TXGL-EFMTEthernet (UDP, TCP)Setting Example 3 (page 10)XGBXBM-D***SXBL-EMTAEthernet (UDP, TCP)Setting Example 4 (page 12)XBC-D***HXBL-EMTAEthernet (UDP, TCP)Setting Example 4 (page 12)XEC-D***HXBL-EMTAEthernet (UDP, TCP)Setting Example 5 (page 14)•Check the combination of the CPU version and the link I/F version with the external device manufacturer. When the versions which are not supported are used, some features may not work properly. Check the versions with the label of each unit or manufacturer's software.XGT/XGB Series FEnet Driver GP-Pro EX Device/PLC Connection Manual4•1:n Connection*1The maximum 32 units connection by UDP connection, the maximum 16 units connection by TCP connection.•n:1 Connection•n:m Connection*2The maximum 32 units connection by UDP connection, the maximum 16 units connection by TCP connection.XGT/XGB Series FEnet Driver GP-Pro EX Device/PLC Connection Manual52Selection of External DeviceSelect the External Device to be connected to the Display.Setup ItemsSetup DescriptionNumber of Devices/PLCsEnter an integer from 1 to 4 to define the number of Devices/PLCs to connect to the display.ManufacturerSelect the manufacturer of the External Device to connect. Select "LS Industrial Systems Co., Ltd.".SeriesSelect the External Device model (series) and the connection method. Select "XGT/XGB Series FEnet".In System configuration, make sure the External Device you are connecting is supported by "XGT/XGB Series FEnet"."1 System Configuration" (page 3)PortSelect the Display port to connect to the External Device.Use System AreaCheck this option to synchronize the system data area of the Display and the device (memory) of the External Device. When synchronized, you can use the External Device’s ladder program to switch the display or display the window on the Display.Cf.GP-Pro EX Reference Manual "LS Area (Direct Access Method Area)"This feature can also be set in GP-Pro EX or in the Display's offline mode.Cf.GP-Pro EX Reference Manual "System Settings [Display Unit] - [System Area] Settings Guide"Cf.Maintenance/Troubleshooting Guide "Main Unit - System Area Settings"

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: LS Industrial Systems Co., Ltd. XGTXGB Series FEnet

评论

发表评论
< /28 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功