您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > Hitachi IES Co., Ltd. H Series Ethernet

Hitachi IES Co., Ltd. H Series Ethernet

  • 文哥
  • 38 人阅读
  • 0 人下载
  • 2019-02-20 11:25:18

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有38人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1Hitachi Industrial Equipment Systems Co., Ltd.H Series Ethernet Driver1System Configuration.......................................................................................................32External Device Selection................................................................................................73Communication Settings..................................................................................................84Setup Items....................................................................................................................525Supported Device...........................................................................................................566Device Code and Address Code....................................................................................647Error Messages..............................................................................................................68H Series Ethernet Driver GP-Pro EX Device/PLC Connection Manual2PREFACEThis manual describes how to connect the Display and the External Device (target PLC).In this manual, the connection procedure is described in the sections identified below:1System ConfigurationThis section lists the types of External Devices and SIO that you can connect."1 System Configuration" (page 3)2External Device SelectionSelect a model (series) of the External Device and its connection method."2 External Device Selection" (page 7)3Communication SettingsThis section shows setting examples for communicating between the Display and the External Device."3 Communication Settings" (page 8)4Setup ItemsThis section describes communication setup items on the Display.Set the Display’s communication settings in GP Pro-EX or in offline mode."4 Setup Items" (page 52)OperationH Series Ethernet Driver GP-Pro EX Device/PLC Connection Manual31System ConfigurationThe following table lists system configurations for connecting Hitachi Industrial Equipment Systems Co., Ltd. External Devices and the Display.Series NameCPULink I/FSIO TypeSetting ExampleHH-4010(CPU3-40H)H-2002(CPU2-20H)H-1002(CPU2-10H)H-702(CPU2-07H)H-302(CPU2-03H)LAN_ETH2LAN_ETHEthernet(TCP)Setting Example 1 (page 8)Ethernet(UDP)Setting Example 2 (page 10)EH-150EH-150(EH-CPU548)EH-150(EH-CPU516)EH-150(EH-CPU448A)EH-150(EH-CPU448)EH-150(EH-CPU316A)EH-150(EH-CPU308A)EH-ETH*1Ethernet(TCP)Setting Example 3 (page 12)Ethernet(UDP)Setting Example 4 (page 14)Connector for ethernet on EH-ETH2Ethernet(TCP)Setting Example 13 (page 32)Ethernet(UDP)Setting Example 14 (page 34)Web ControllerEH-WD10DREH-WA23DREthernet port on CPUEthernet(TCP)Setting Example 5 (page 16)Ethernet(UDP)Setting Example 6 (page 18)EHVEHV-CPU128EHV-CPU64EHV-CPU32EHV-CPU16Ethernet port on CPUEthernet(TCP)Setting Example 7 (page 20)Ethernet(UDP)Setting Example 8 (page 22)EH-ETH*1Ethernet(TCP)Setting Example 9 (page 24)Ethernet(UDP)Setting Example 10 (page 26)Connector for ethernet on EH-ETH2Ethernet(TCP)Setting Example 15 (page 36)Ethernet(UDP)Setting Example 16 (page 38)H Series Ethernet Driver GP-Pro EX Device/PLC Connection Manual4EHVEHV-CPU128EHV-CPU64EHV-CPU32EHV-CPU16Ethernet communication port on EH-ORML*2 *3Ethernet(TCP)Setting Example 11 (page 28)Ethernet(UDP)Setting Example 12 (page 30)Ethernet communication port on EH-R2LH *2 *4Ethernet(TCP)Setting Example 17 (page 40)Ethernet(UDP)Setting Example 18 (page 42)MICRO-EHEH-20EH-40EH-64Communication port on EH-OBETH *5Ethernet(TCP)Setting Example 19 (page 44)Ethernet(UDP)Setting Example 20 (page 47)MICRO-EHVMVH-A64MVH-D64MVH-A40MVH-D40Ethernet port on basic unitEthernet(TCP)Setting Example 21 (page 50)*1When connecting with Display, EH-ETH with SOFTWARE VER.06 or later is required. (Check the label of EH-ETH main body for the version.)*2The following CPU ROM versions are required to use the remote communications module.*3EH-ORMM is required to use EH-ORML.*4EH-RMAH is required to use EH-R2LH.*5The following CPU ROM versions are required to use EH-OBETH.Series NameCPULink I/FSIO TypeSetting ExampleCPUSupported versionsEHV-CPU128ROM Ver.0117 or laterEHV-CPU64ROM Ver.1117 or laterEHV-CPU32ROM Ver.2117 or laterEHV-CPU16ROM Ver.3117 or laterCPUSupported versionsEH-20MFG No. 05Gxx or laterEH-40MFG No. 05Gxx or laterEH-64MFG No. 05Gxx or laterH Series Ethernet Driver GP-Pro EX Device/PLC Connection Manual5Connection Configuration[1:1 Connection][1:n Connection][n:1Connection][n:m Connection]DisplayExternal DeviceHUBEthernetUnitDisplayExternal DeviceHUBEthernetUnitExternal DeviceEthernetUnitEthernetUDP Connection: Up to 32 unitsTCP Connection: Up to 16 unitsDisplayHUBEthernetH Series, MICRO-EH Series: Up to 2 unitsEH-150 Series, EHV Series,Web Controller: Up to 4 unitsDisplayEthernet UnitDisplayHUBEthernetH Series, MICRO-EH Series: Up to 2 unitsEH-150 Series, EHV Series,Web Controller: Up to 4 unitsDisplayExternal DeviceEthernet UnitExternal DeviceEthernet UnitUDP Connection: Up to 32 unitsTCP Connection: Up to 16 units

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: Hitachi IES Co., Ltd. H Series Ethernet

相关搜索

Hitachi IES Co Ltd Series Ethernet

评论

发表评论
< /68 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功