您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > Fuji Electric Co.,Ltd. MICREX-SX Series SIO

Fuji Electric Co.,Ltd. MICREX-SX Series SIO

  • 文哥
  • 13 人阅读
  • 0 人下载
  • 2019-02-20 11:25:16

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有13人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1Fuji Electric Co.,Ltd. MICREX-SX Series SIO Driver1System Configuration.......................................................................................................32Selection of External Device............................................................................................73Example of Communication Setting.................................................................................84Setup Items....................................................................................................................155Cable Diagram...............................................................................................................206Supported Device...........................................................................................................387Device Code and Address Code....................................................................................568Error Messages..............................................................................................................57MICREX-SX Series SIO Driver GP-Pro EX Device/PLC Connection Manual2IntroductionThis manual describes how to connect the Display and the External Device (target PLC).In this manual, the connection procedure will be described by following the below sections:1System ConfigurationThis section shows the types of External Devices which can be connected and SIO type."1 System Configuration" (page 3)2Selection of External DeviceSelect a model (series) of the External Device to be connected and connection method."2 Selection of External Device" (page 7)3Example of Communication SettingsThis section shows setting examples for communicating between the Display and the External Device."3 Example of Communication Setting" (page 8)4Setup ItemsThis section describes communication setup items on the Display.Set communication settings of the Display with GP-Pro Ex or in offline mode."4 Setup Items" (page 15)5Cable DiagramThis section shows cables and adapters for connecting the Display and the External Device."5 Cable Diagram" (page 20)OperationMICREX-SX Series SIO Driver GP-Pro EX Device/PLC Connection Manual31System ConfigurationThe system configuration in the case when the External Device of Fuji Electric Co., Ltd. and the Display are connected is shown.Connection Configuration•1:1 ConnectionSeriesCPULink I/FSIO TypeSetting ExampleCable DiagramSPHSPH200(NP1PH-08 / NP1PH-16)SPH300(NP1PS-32 / NP1PS-32R / NP1PS-74 / NP1PS-74R / NP1PS-117 / NP1PS-117R)SPH2000(NP1PM-48E)Loader Connection Connector on CPU unitRS232C"Setting Example 1" (page 8)"Cable Diagram 1" (page 20)NP1L-RS1RS232C"Setting Example 2" (page 9)"Cable Diagram 2" (page 22)RS422/485(4wire)"Setting Example 3" (page 10)"Cable Diagram 3" (page 24)NP1L-RS2RS232C"Setting Example 2" (page 9)"Cable Diagram 2" (page 22)NP1L-RS4RS422/485(4wire)"Setting Example 3" (page 10)"Cable Diagram 3" (page 24)NP1L-TL1 + FFK120A-C10 (RS232C interface)*1*1Version 0604 or later interface is required.RS232C"Setting Example 4" (page 11)"Cable Diagram 4" (page 30)NP1L-TL1 + FFK120A-C10 (RS485 interface)*1RS422/485(4wire)"Setting Example 5" (page 13)"Cable Diagram 5" (page 32)•Only one Display can be connected to one CPU or one Link I/F’s SIO port.•When 2 or more displays are connected to 2 or more CPUs and Link I/F’s SIO ports, the error below may be displayed when 2 or more Displays are activated simultaneously.“Error has been responded for initial communication command (Error Code: [Hex])”If an error occurs, wait for 5 or more seconds to activate the Display.DisplayExternal DeviceMICREX-SX Series SIO Driver GP-Pro EX Device/PLC Connection Manual4IPC COM PortWhen connecting IPC with an External Device, the COM port used depends on the series and SIO type. Please refer to the IPC manual for details.Usable portSeriesUsable PortRS-232CRS-422/485(4 wire)RS-422/485(2 wire)PS-2000BCOM1*1, COM2, COM3*1, COM4*1The RI/5V can be switched. Use the IPC’s switch to change if necessary.--PS-3450A, PS-3451A,PS3000-BA, PS3001-BDCOM1, COM2*1*2COM2*1*2COM2*1*2PS-3650A (T41 model),PS-3651A (T41 model)COM1*1--PS-3650A (T42 model),PS-3651A (T42 model)COM1*1*2, COM2COM1*1*2COM1*1*2PS-3700A (Pentium®4-M)PS-3710ACOM1*1, COM2*1, COM3*2, COM4*2Set up the SIO type with the DIP Switch. Please set up as follows according to SIO type to be used.COM3*2COM3*2PS-3711ACOM1*1, COM2*2COM2*2COM2*2PS4000*3*3When making communication between an External Device and COM port on the Expansion slot, only RS-232C is supported. However, ER (DTR/CTS) control cannot be executed because of the specification of COM port.For connection with External Device, use user-created cables and disable Pin Nos. 1, 4, 6 and 9.Please refer to the IPC manual for details of pin layout.COM1, COM2--PL3000COM1*1*2, COM2*1, COM3, COM4COM1*1*2COM1*1*2PE-4000B Atom N270COM1, COM2--PE-4000B Atom N2600COM1, COM2COM3*4, COM4*4, COM5*4, COM6*4*4Set up the SIO type with the BIOS. Please refer to the IPC manual for details of BIOS.COM3*4, COM4*4, COM5*4, COM6*4PS5000 (Slim Panel Type Core i3 Model) *5 *6COM1, COM2*4COM2*4COM2*4PS5000 (Slim Panel Type Atom Model) *5 *6COM1, COM2*7COM2*7COM2*7PS5000 (Enclosed Panel Type)*8COM1--PS5000 (Modular Type) *5 *6COM1*7COM1*7COM1*7MICREX-SX Series SIO Driver GP-Pro EX Device/PLC Connection Manual5DIP Switch settings (PL3000 / PS3000 Series)RS-232C*5When setting up communication between an External Device and the RS-232C/422/485 interface module, use the IPC (RS-232C) or PS5000 (RS-422/485) cable diagrams. However, when using PFXZPBMPR42P2 in a RS-422/485 (4-wire) configuration with no flow control, connect 7.RTS+ and 8.CTS+, and connect 6.RTS- and 9.CTS-.When using RS-422/485 communication with External Devices, you may need to reduce the transmission speed and increase the TX Wait time.*6To use RS-422/485 communication on the RS-232C/422/485 interface module, the DIP Switch setting is required. Please refer to "Knowledge Base" (FAQs) on the support site. (http://www.pro- face.com/trans/en/manual/1001.html)*7Set up the SIO type with the DIP Switch. Please refer to the IPC manual for details of DIP Switch.*8For the connection with the External Device, on the user-created cable read as if the connector on the Display-side is a M12 A-coding 8 pin socket. The pin assignment is the same as described in the cable diagram. For the M12 A-coding connector, use PFXZPSCNM122.DIP SwitchSettingDescription1OFF*1*1When using PS-3450A, PS-3451A, PS3000-BA and PS3001-BD, turn ON the set value.Reserved (always OFF)2OFFSIO type: RS-232C3OFF4OFFOutput mode of SD (TXD) data: Always output5OFFTerminal resistance (220) insertion to SD (TXD): None6OFFTerminal resistance (220) insertion to RD (RXD): None7OFFShort-circuit of SDA (TXA) and RDA (RXA): Not available8OFFShort-circuit of SDB (TXB) and RDB (RXB): Not available9OFFRS (RTS) Auto control mode: Disabled10OFFSettingsFAQ IDPFXZPBMPR42P2, RS422/485 change methodFA263858PFXZPBMPR42P2 termination resistor settingFA263974PFXZPBMPR44P2, RS422/485 change methodFA264087PFXZPBMPR44P2 termination resistor settingFA264088

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: Fuji Electric Co.,Ltd. MICREX-SX Series SIO

评论

发表评论
< /58 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功