您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > Emerson Process Management. ROC Plus SIO

Emerson Process Management. ROC Plus SIO

  • 文哥
  • 30 人阅读
  • 0 人下载
  • 2019-02-20 11:25:13

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有30人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1Emerson Process Management ROC Plus SIO Driver1System Configuration.......................................................................................................32External Device Selection................................................................................................73Communication Settings..................................................................................................84Setup Items....................................................................................................................105Cable Diagrams.............................................................................................................156Supported Devices.........................................................................................................277Error Messages..............................................................................................................31ROC Plus SIO Driver GP-Pro EX Device/PLC Connection Manual2IntroductionThis manual describes how to connect the display unit and the external device (target controller).In this manual, the connection procedure is described in the sections identified below.1System ConfigurationThis section lists the types of external devices and SIO that you can connect.�"1 System Configuration" (page 3)2External Device SelectionSelect a model (series) of the external device and its connection method. �"2 External Device Selection" (page 7)3Communication SettingsThis section shows setting examples for communicating between the display unit and the external device.�"3 Communication Settings" (page 8)4Setup ItemsThis section describes communication setup items on the display unit.Set the display unit’s communication settings in GP Pro-EX or in offline mode.�"4 Setup Items" (page 10)5Cable DiagramsThis section shows cables and adapters for connecting the display unit and the external device.�"5 Cable Diagrams" (page 15)OperationROC Plus SIO Driver GP-Pro EX Device/PLC Connection Manual31System ConfigurationThe following table lists system configurations for connecting Emerson Process Management external devices to display units.SeriesCPULink I/FSIO TypeSetting ExampleCable DiagramROCROC300LOI Port,EIA-232 (optional expansion module)RS-232C"Setting Example 1" (page 8)"Cable Diagram 1" (page 15)EIA-485 / RS485 (optional expansion module)RS-422/485 (2-wire)"Setting Example 1" (page 8)"Cable Diagram 4" (page 21)ROC800 (809, 827)LOI RS-232D PortRS-232C"Setting Example 1" (page 8)"Cable Diagram 2" (page 17)EIA-485 / RS485 (optional expansion module)RS-422/485 (2-wire)"Setting Example 1" (page 8)"Cable Diagram 4" (page 21)ROCPACROCPAC 306ROCPAC 312ROCPAC 364LOI Port,EIA-232 (optional expansion module)RS-232C"Setting Example 1" (page 8)"Cable Diagram 1" (page 15)EIA-485 / RS485 (optional expansion module)RS-422/485 (2-wire)"Setting Example 1" (page 8)"Cable Diagram 4" (page 21)FloBossFB103FB107LOI Port,EIA-232RS-232C"Setting Example 1" (page 8)"Cable Diagram 1" (page 15)EIA-485 / RS485RS-422/485 (2-wire)"Setting Example 1" (page 8)"Cable Diagram 4" (page 21)FB407FB503FB504LOI Operator Interface CableRS-232C"Setting Example 1" (page 8)"Cable Diagram 3" (page 19)EIA-485 / RS485 (optional expansion module)RS-422/485 (2-wire)"Setting Example 1" (page 8)"Cable Diagram 4" (page 21)ROC Plus SIO Driver GP-Pro EX Device/PLC Connection Manual4�IPC COM PortWhen connecting IPC with an External Device, the COM port used depends on the series and SIO type. Please refer to the IPC manual for details.Usable portSeriesUsable PortRS-232CRS-422/485(4 wire)RS-422/485(2 wire)PS-2000BCOM1*1, COM2, COM3*1, COM4*1The RI/5V can be switched. Use the IPC’s switch to change if necessary.--PS-3450A, PS-3451A,PS3000-BA, PS3001-BDCOM1, COM2*1*2COM2*1*2COM2*1*2PS-3650A (T41 model),PS-3651A (T41 model)COM1*1--PS-3650A (T42 model),PS-3651A (T42 model)COM1*1*2, COM2COM1*1*2COM1*1*2PS-3700A (Pentium®4-M)PS-3710ACOM1*1, COM2*1, COM3*2, COM4*2Set up the SIO type with the DIP Switch. Please set up as follows according to SIO type to be used.COM3*2COM3*2PS-3711ACOM1*1, COM2*2COM2*2COM2*2PS4000*3*3When making communication between an External Device and COM port on the Expansion slot, only RS-232C is supported. However, ER (DTR/CTS) control cannot be executed because of the specification of COM port. For connection with External Device, use user-created cables and disable Pin Nos. 1, 4, 6 and 9. Please refer to the IPC manual for details of pin layout.COM1, COM2--PL3000COM1*1*2, COM2*1, COM3, COM4COM1*1*2COM1*1*2PE-4000B Atom N270COM1, COM2--PE-4000B Atom N2600COM1, COM2COM3*4, COM4*4, COM5*4, COM6*4*4Set up the SIO type with the BIOS. Please refer to the IPC manual for details of BIOS.COM3*4, COM4*4, COM5*4, COM6*4PS5000 (Slim Panel Type Core i3 Model) *5 *6*5When setting up communication between an External Device and the RS-232C/422/485 interface module, use the IPC (RS-232C) or PS5000 (RS-422/485) cable diagrams. However, when using PFXZPBMPR42P2 in a RS-422/485 (4-wire) configuration with no flow control, connect 7.RTS+ and 8.CTS+, and connect 6.RTS- and 9.CTS-. When using RS-422/485 communication with External Devices, you may need to reduce the transmission speed and increase the TX Wait time.COM1, COM2*4COM2*4COM2*4PS5000 (Slim Panel Type Atom Model) *5 *6COM1, COM2*7COM2*7COM2*7PS5000 (Enclosed Panel Type)*8COM1--PS5000 (Modular Type) *5 *6COM1*7COM1*7COM1*7ROC Plus SIO Driver GP-Pro EX Device/PLC Connection Manual5DIP Switch settings (PL3000 / PS3000 Series)RS-232C*6To use RS-422/485 communication on the RS-232C/422/485 interface module, the DIP Switch setting is required. Please refer to "Knowledge Base" (FAQs) on the support site. (http://www.pro- face.com/trans/en/manual/1001.html)*7Set up the SIO type with the DIP Switch. Please refer to the IPC manual for details of DIP Switch.*8For the connection with the External Device, on the user-created cable read as if the connector on the Display-side is a M12 A-coding 8 pin socket. The pin assignment is the same as described in the cable diagram. For the M12 A-coding connector, use PFXZPSCNM122.DIP SwitchSettingDescription1OFF*1*1When using PS-3450A, PS-3451A, PS3000-BA and PS3001-BD, turn ON the set value.Reserved (always OFF)2OFFSIO type: RS-232C3OFF4OFFOutput mode of SD (TXD) data: Always output5OFFTerminal resistance (220Ω) insertion to SD (TXD): None6OFFTerminal resistance (220Ω) insertion to RD (RXD): None7OFFShort-circuit of SDA (TXA) and RDA (RXA): Not available8OFFShort-circuit of SDB (TXB) and RDB (RXB): Not available9OFFRS (RTS) Auto control mode: Disabled10OFFSettingsFAQ IDPFXZPBMPR42P2, RS422/485 change methodFA263858PFXZPBMPR42P2 termination resistor settingFA263974PFXZPBMPR44P2, RS422/485 change methodFA264087PFXZPBMPR44P2 termination resistor settingFA264088

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: Emerson Process Management. ROC Plus SIO

评论

发表评论
< /31 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功