您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > Digital Electronics Corporation Device Data Copy Tool Guide

Digital Electronics Corporation Device Data Copy Tool Guide

  • 文哥
  • 8 人阅读
  • 0 人下载
  • 2019-02-20 11:25:07

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有8人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1YASKAWA Electric CorporationDevice Data Copy Tool Guide1General Description.........................................................................................................22Install................................................................................................................................53External Device Data Copy..............................................................................................74Setup Items....................................................................................................................135Error Messages..............................................................................................................196Restriction......................................................................................................................217Appendix........................................................................................................................23YASKAWA Electric Corporation Device Data Copy Tool Guide GP-Pro EX Device/PLC Connection Manual21General Description1.1What is the Device Data Copy ToolWhen transferring a ladder file to the External Device using a Windows application such as a ladder software, the ladder software needs to be connected to the External Device.Example)1PC with an application such as ladder software installed.2External Device to be communicated with.3Cable for transferGP-Pro EX can transfer ladder files from the Display using the Device Data Copy Tool.Example)1PC with an application such as ladder software installed.2External Device to be communicated with.3Display that executes transfer.4Storage device (USB storage or CF card)5GP-Pro EX driver corresponding to the External Device.Using the Device Data Copy Tool eases tooling change work because ladder files can be transferred to the External Device without using a computer.12312345YASKAWA Electric Corporation Device Data Copy Tool Guide GP-Pro EX Device/PLC Connection Manual31.2Mechanism of the Device Data Copy ToolThere are 2 procedures of the Device Copy Tool.1Store the ladder file and the External Device data transfer execution file to the storage device.1Computer in which the ladder software is installed.2The storage device to store the ladder file and the External Device data transfer execution file.2Transfer all ladder files storage in the storage device to the External Device.1Storage device that stores ladder files and External Device data transfer execution files.2Display that executes transfer.3External Device to be communicated with.4USB port or CF card slot.5GP-Pro EX driver corresponding to the External Device.12123455YASKAWA Electric Corporation Device Data Copy Tool Guide GP-Pro EX Device/PLC Connection Manual41.3Operation EnvironmentThe following environment is required to use the Device Data Copy Tool.•Compatible driverYASKAWA Electric Corporation MP Ethernet/MECHATROLINK Driver•Compatible External DeviceCompatible to the MP2000 Series (include MPU-01) and MP3000 Series (include SubCPU and Σ-7C Controller Section) that YASKAWA Electric Corporation MP Ethernet/MECHATROLINK Driver supports. Refer to the YASKAWA Electric Corporation MP Ethernet/MECHATROLINK Driver Manual for details.•Compatible ladder softwareYASKAWA Electric Corporation MPE720 (Ver.7.11 or more)YASKAWA Electric Corporation MPE720 (Ver.6.04 or more)YASKAWA Electric Corporation MPE720 (Ver. 5.38 or more. New ladder is not supported.)•Compatible OSMicrosoft® Windows® XP (All editions of 32-bit versions)Microsoft® Windows Vista® (All editions of 32-bit versions: Service Pack 2 or later)Microsoft® Windows® 7 (All editions of 32-bit versions)Microsoft® Windows® 7 (All editions of 64-bit versions: Service Pack 1 or later)Microsoft® Windows® 8 / Microsoft® Windows® 8.1 (All editions of 32-bit/64-bit versions)Microsoft® Windows® 10 (32-bit/64-bit versions of Home, Pro, and Enterprise)YASKAWA Electric Corporation Device Data Copy Tool Guide GP-Pro EX Device/PLC Connection Manual52Install2.1Install of Device Data Copy Tool1Set the Disk of GP-Pro EX to the drive to start the installer.2When the install screen is displayed, Click “Data Copy Tool”3The dialog box, “Welcome to the InstallShield Wizard for Device Data Copy Tool” is displayed, and go forward with the installation following the directions of the wizard.4Select the install destination in the “Install Data Copy Tool to:” dialog box, and click [Install] to install the Device Data Copy Tool.•Install the Device Data Copy Tool under the administrative privileges.•Be sure to quit all application programs and close (disable) all resident programs, such as virus detection software.

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: Digital Electronics Corporation Device Data Copy Tool Guide

评论

发表评论
< /23 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功