您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > CoDeSys Automation Alliance CoDeSys V3 Ethernet Driver

CoDeSys Automation Alliance CoDeSys V3 Ethernet Driver

  • 文哥
  • 10 人阅读
  • 0 人下载
  • 2019-02-20 11:25:05

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有10人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1 CoDeSys Automation Alliance CoDeSys V3 Ethernet Driver1System Configuration.......................................................................................................32External Device Selection................................................................................................53Communication Settings..................................................................................................64Setup Items......................................................................................................................95Supported Devices.........................................................................................................136Device Code and Address Code....................................................................................197Error Messages..............................................................................................................20CoDeSys V3 Ethernet Driver GP-Pro EX Device/PLC Connection Manual2IntroductionThis manual describes how to connect the Display and the External Device (target PLC).In this manual, the connection procedure will be described in the sections identified below:1System ConfigurationThis section lists the types of External Devices and SIO that you can connect."1 System Configuration" (page 3)2External Device SelectionSelect a model (series) of the External Device and its connection method."2 External Device Selection" (page 5)Operation3Communication SettingsThis section shows setting examples for communicating between the Display and the External Device."3 Communication Settings" (page 6)4Setup ItemsThis section describes communication setup items on the Display. Set the Display’s communication settings in GP Pro-EX or in off-line mode."4 Setup Items" (page 9)CoDeSys V3 Ethernet Driver GP-Pro EX Device/PLC Connection Manual31System ConfigurationThe system configuration for the Display connected to the CoDeSys Automation Alliance External Device is shown below.Connection Configuration•1:1 Connection•1:n ConnectionSeriesCPULink I/FCommunication MethodSetting Example3S-Smart Software Solutions GmbH CODESYS Control Win V3PC/ATEthernet InterfaceEthernet (TCP)"Setting Example 1" (page 6)Hitachi Industrial Equipment Systems Co., Ltd.EHV+1006102510511102Ethernet InterfaceEthernet (TCP)"Setting Example 1" (page 6)Lenze Vertrieb GmbH Controller 3200C3200CEthernet InterfaceEthernet (TCP)"Setting Example 1" (page 6)•Please refer to the latest list of the External Device to be supported by this driver on the Pro-face’s website.http://www.pro-face.com/product/soft/gpproex/driver/driver.html•This driver does not support GP3000 Series, LT3000 Series, GP-4100 Series (Monochrome Model), GP-4*01TM and GP-Rear Module.CoDeSys V3 Ethernet Driver GP-Pro EX Device/PLC Connection Manual4•1:n Connection (Gateway connection)•n:1 Connection•n:m Connection*The number of Displays you can connect depends on the External Device. Check the specifications of the External Device.CoDeSys V3 Ethernet Driver GP-Pro EX Device/PLC Connection Manual52External Device SelectionSelect the External Device to be connected to the Display.Setup ItemsSetup DescriptionNumber of Devices/PLCsUse an integer from 1 to 2 to enter the number of Devices/PLCs to connect to the display.•When you set up the CoDeSys Automation Alliance CoDeSys V3 Ethernet driver, you can connect simultaneously up to two drivers (models that support four drivers) or one driver (models that support two drivers). ManufacturerSelect the manufacturer of the External Device to be connected. Select "CoDeSys Automation Alliance".SeriesSelect a model (series) of the External Device to be connected and connection method. Select "CoDeSys V3 Ethernet".Check the External Device which can be connected in "CoDeSys V3 Ethernet" in system configuration."1 System Configuration" (page 3)PortSelect the Display port to be connected to the External Device. Select [Ethernet (TCP)].Use System AreaCheck this option to synchronize the system data area of the Display and the device (memory) of the External Device. When synchronized, you can use the External Device’s ladder program to switch the display or display the window on the Display.Cf.GP-Pro EX Reference Manual "LS Area (Direct Access Method Area)"This feature can also be set in GP-Pro EX or in the Display's offline mode.Cf.GP-Pro EX Reference Manual "System Settings [Display Unit] - [System Area] Settings Guide"Cf.Maintenance/Troubleshooting Guide "Main Unit - System Area Settings"

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: CoDeSys Automation Alliance CoDeSys V3 Ethernet Driver

评论

发表评论
< /20 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功