您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > CoDeSys Automation Alliance CoDeSys SIO

CoDeSys Automation Alliance CoDeSys SIO

  • 文哥
  • 38 人阅读
  • 0 人下载
  • 2019-02-20 11:25:03

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有38人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1 CoDeSys Automation Alliance CoDeSys SIO Driver 1. System Configuration .................................................................................. 3 2. Selection of External Device ........................................................................ 7 3. Example of Communication Setting ............................................................. 8 4. Setup Items ................................................................................................ 10 5. Cable Diagrams ......................................................................................... 15 6. Supported Device Address ......................................................................... 17 7. Device Code and Address Code ................................................................. 23 8. Error Messages .......................................................................................... 24 CoDeSys SIO Driver GP-Pro EX Device/PLC Connection Manual 2 Introduction This manual describes how to connect display and the External Device (target PLC). In this manual, the connection procedure will be described by the following sections: 1 System Configuration This section shows the types of external devices which can be connected ”1 System Configuration” 2 Selection of External Device Select a model (series) of external to be connected and connection method ”2 Selection of External Device” 3 Example of Communication Settings This section shows setting examples for communicating between the display and the external device ”3 Example of communication settings” 4 Setup Items This section describes communication setup items on the Display. Set communication settings of the Display with GP-Pro Ex or in off-line mode. ”4 Setup Items” Operation CoDeSys SIO Driver GP-Pro EX Device/PLC Connection Manual 3 1. System Configuration The system configuration for CoDeSys Automation Alliance devices and the display connected are shown as follows. Series CPU Link I/F SIO Type Setting Example Cable Diagram BOSCH Rexroth Indra Control L20 CML20.1-NP-120-NA-NNNN-NW X3C (RS232) RS-232C Setting Example 1 (page 8) Cable Diagram 1 (page15) Indra Control L40 X31 RS-232C Setting Example 1 (page 8) Cable Diagram 1 (page15) Indra Control PPC-R22 SIO Port RS-232C Setting Example 1 (page 8) Cable Diagram 1 (page15) 3S SoftPLC Windows NT SIO Port RS-232C Setting Example 1 (page 8) Cable Diagram 1 (page15) CoDeSys SIO Driver GP-Pro EX Device/PLC Connection Manual 4 ■ IPC COM Port When connecting IPC with an External Device, the COM port used depends on the series and SIO type. Please refer to the IPC manual for details. Usable port Series Usable Port RS-232C RS-422/485(4 wire) RS-422/485(2 wire) PS-2000B COM1*1, COM2, COM3*1, COM4 - - PS-3450A, PS-3451A, PS3000-BA, PS3001-BD COM1, COM2*1*2 COM2*1*2 COM2*1*2 PS-3650A (T41 model), PS-3651A (T41 model) COM1*1 - - PS-3650A (T42 model), PS-3651A (T42 model) COM1*1*2, COM2 COM1*1*2 COM1*1*2 PS-3700A (Pentium®4-M) PS-3710A COM1*1, COM2*1, COM3*2, COM4 COM3*2 COM3*2 PS-3711A COM1*1, COM2*2 COM2*2 COM2*2 PS4000*3 COM1, COM2 - - PL3000 COM1*1*2, COM2*1, COM3, COM4 COM1*1*2 COM1*1*2 PE-4000B Atom N270 COM1, COM2 - - PE-4000B Atom N2600 COM1, COM2 COM3*4, COM4*4, COM5*4, COM6*4 COM3*4, COM4*4, COM5*4, COM6*4 PS5000 (Slim Panel Type Core i3 Model)*5*6 COM1, COM2*4 COM2*4 COM2*4 PS5000 (Slim Panel Type Atom Model) *5*6 COM1, COM2*7 COM2*7 COM2*7 PS5000 (Enclosed Panel Type) *8 COM1 -- PS5000 (Modular Type) *5*6 COM1*7 COM1*7 COM1*7 *1 The RI/5V can be switched. Use the IPC’s switch to change if necessary. *2 Set up the SIO type with the DIP Switch. Please set up as follows according to SIO type to be used. *3 When making communication between an External Device and COM port on the Expansion slot, only RS-232C is supported. However, ER (DTR/CTS) control cannot be executed because of the specification of COM port. For connection with External Device, use user-created cables and disable Pin Nos. 1, 4, 6 and 9. Please refer to the IPC manual for details of pin layout. *4 Set up the SIO type with the BIOS. Please refer to the IPC manual for details of BIOS. CoDeSys SIO Driver GP-Pro EX Device/PLC Connection Manual 5 *5 When setting up communication between an External Device and the RS-232C/422/485 interface module, use the IPC (RS-232C) or PS5000 (RS-422/485) cable diagrams. However, when using PFXZPBMPR42P2 in a RS-422/485 (4-wire) configuration with no flow control, connect 7.RTS+ and 8.CTS+, and connect 6.RTS- and 9.CTS-. When using RS-422/485 communication with External Devices, you may need to reduce the transmission speed and increase the TX Wait time. *6 To use RS-422/485 communication on the RS-232C/422/485 interface module, the DIP Switch setting is required. Please refer to "Knowledge Base" (FAQs) on the support site. (http://www.pro-face.com/trans/en/manual/1001.html) Settings FAQ ID PFXZPBMPR42P2, RS422/485 change method FA263858 PFXZPBMPR42P2 termination resistor setting FA263974 PFXZPBMPR44P2, RS422/485 change method FA264087 PFXZPBMPR44P2 termination resistor setting FA264088 *7 Set up the SIO type with the DIP Switch. Please refer to the IPC manual for details of DIP Switch. *8 For the connection with the External Device, on the user-created cable read as if the connector on the Display-side is a M12 A-coding 8 pin socket. The pin assignment is the same as described in the cable diagram. For the M12 A-coding connector, use PFXZPSCNM122. DIP Switch settings (PL3000 / PS3000 Series) RS-232C DIP Switch Setting Description 1 OFF*1 Reserved (always OFF) 2 OFF SIO type: RS-232C 3 OFF 4 OFF Output mode of SD (TXD) data: Always output 5 OFF Terminal resistance (220Ω) insertion to SD (TXD): None 6 OFF Terminal resistance (220Ω) insertion to RD (RXD): None 7 OFF Short-circuit of SDA (TXA) and RDA (RXA): Not available 8 OFF Short-circuit of SDB (TXB) and RDB (RXB): Not available 9 OFF RS (RTS) Auto control mode: Disabled 10 OFF *1 When using PS-3450A, PS-3451A, PS3000-BA and PS3001-BD, turn ON the set value.

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: CoDeSys Automation Alliance CoDeSys SIO

评论

发表评论
< /24 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功