您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > HMI > Cognex Corporation In-Sight Vision Systems

Cognex Corporation In-Sight Vision Systems

  • 文哥
  • 15 人阅读
  • 0 人下载
  • 2019-02-20 11:25:02

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有15人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1Cognex Corporation In-Sight Vision Systems Driver1System Configuration.......................................................................................................32External Devices Selection..............................................................................................53Communication Settings..................................................................................................64Setup Items......................................................................................................................85Supported Devices.........................................................................................................136Device Code and Address Code....................................................................................177Error Messages..............................................................................................................18In-Sight Vision Systems Driver GP-Pro EX Device/PLC Connection Manual2IntroductionThis manual describes how to connect the Display and the External Device (target sensor).In this manual, connection procedures are described in the sections identified below.1System ConfigurationThis section lists the types of External Devices and SIO that you can connect."1 System Configuration" (page 3)2External Device SelectionSelect a model (series) of the External Device and its connection method."2 External Devices Selection" (page 5)3Communication SettingsThis section shows setting examples for communicating between the Display and the External Device."3 Communication Settings" (page 6)4Setup ItemsThis section describes communication setup items on the Display.Set the Display’s communication settings in GP Pro-EX or in offline mode."4 Setup Items" (page 8)5[Image Sensor Display] SettingsSet the [Image Sensor Display] in GP Pro-EX.Cf.GP-Pro EX Reference ManualOperationIn-Sight Vision Systems Driver GP-Pro EX Device/PLC Connection Manual31System ConfigurationThe following section shows system configurations for connecting Cognex Corporation External Device and the Display.SeriesCPULink I/FSIO TypeSetting ExampleIn-Sight 7000 Series Vision SystemsEthernet port on the External DeviceEthernet (TCP)"Setting Example 1" (page 6)In-Sight 5000 Series Vision SystemsEthernet port on the External DeviceEthernet (TCP)"Setting Example 1" (page 6)In-Sight Micro Vision SystemsEthernet port on the External DeviceEthernet (TCP)"Setting Example 1" (page 6)•This driver does not support GP-4100 Series (Monochrome Model) and LT3000 Series.•Among GP-3000 Series units, you can use this driver with GP-3300/3400/3500/3600 Series Rev 4 or later units (excluding multi-media class). •Depending on the image size (resolution) used with your External Device, set up the maximum number of image sensor display parts on one screen as follows.•With high-resolution or color images that require large amounts of data, the image refresh rate becomes slower. You can speed up the screen refresh rate by reducing the image display size from the Individual Device Settings dialog box's [Resolution] field, or the device address's IMAGE/Downscale feature.•This driver only supports External Devices that can use In-Sight Explorer.•The firmware version for the External Device should be version 4.9 or later.If the firmware version is not version 4.9 or later, the image may display as either noise (snow) or become blacked out. Additionally, if the External Device becomes disabled while the image is displayed or communication is interrupted, the image may display as either noise (snow) or become blacked out.If the image displays as noise (snow) or become blacked out, check the firmware version and cable connection.DisplayMaximum image size is 640 x 480Maximum image size is 800 x 600Maximum image size is 1280 x 1024GP3000GP-4*01TM32N/AGP4000*1LT-4*01TMSP5000IPCPC/AT*1Except GP-4100 Series (Monochrome Model) and GP-4*01TM331In-Sight Vision Systems Driver GP-Pro EX Device/PLC Connection Manual4Connection Configuration1:1 Connection1:n Connection•Two or more Displays cannot be connected to one External Device.•You cannot use Cognex Corporation configuration tools such as In-Sight Connection Manager or In-Sight Explorer to connect the External Device and Display.DisplayExternal DeviceHUBHUBDisplayExternal DeviceExternal DeviceExternal DeviceMaximum number of External Devices: 16In-Sight Vision Systems Driver GP-Pro EX Device/PLC Connection Manual52External Devices SelectionSelect the External Device to be connected to the Display.Setup ItemsSetup DescriptionNumber of Devices/PLCsEnter an integer from 1 to 4 to define the number of Devices/PLCs to connect to the display.ManufacturerSelect the manufacturer of the External Device to connect. Select "Cognex Corporation".SeriesSelect the External Device model (series) and the connection method. Select "In-Sight Vision Systems".In System configuration, make sure the External Device you are connecting is supported by "In-Sight Vision Systems"."1 System Configuration" (page 3)PortSelect the Display port to connect to the External Device.Use System AreaCheck this option to synchronize the system data area of the Display and the device (memory) of the External Device. When synchronized, you can use the External Device’s ladder program to switch the display or display the window on the Display.Cf.GP-Pro EX Reference Manual "LS Area (Direct Access Method Area)"This feature can also be set in GP-Pro EX or in the Display's offline mode.Cf.GP-Pro EX Reference Manual "System Settings [Display Unit] - [System Area] Settings Guide"Cf.Maintenance/Troubleshooting Guide "Main Unit - System Area Settings"

文哥
文哥
  • 4231

    文档
  • 0

    金币
Ta的主页 发私信

4231篇文档

文档介绍: Cognex Corporation In-Sight Vision Systems

评论

发表评论
< /19 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功