您好,欢迎访问联智博库

上传文档

当前位置:首页 > 工控技术 > PLC > 1768-L43 and 1768-L45 CompactLogix Controllers Quick Start

1768-L43 and 1768-L45 CompactLogix Controllers Quick Start

  • 小库
  • 13 人阅读
  • 0 人下载
  • 2019-02-20 11:07:00

还剩... 页未读,继续阅读

免费阅读已结束,点击付费阅读剩下 ...

¥ 0 元,已有13人购买

免费阅读

阅读已结束,您可以下载文档离线阅读

¥ 1 元,已有0人下载

付费下载

文档部分内容文本提取

1768 CompactLogix SystemCatalog Numbers 1768-L43 and 1768-L45 CompactLogix ControllersQuick StartImportant User InformationSolid state equipment has operational characteristics differing from those of electromechanical equipment. Safety Guidelines for the Application, Installation and Maintenance of Solid State Controls (publication SGI-1.1 available from your local Rockwell Automation sales office or online at http://www.rockwellautomation.com/literature/) describes some important differences between solid state equipment and hard-wired electromechanical devices. Because of this difference, and also because of the wide variety of uses for solid state equipment, all persons responsible for applying this equipment must satisfy themselves that each intended application of this equipment is acceptable.In no event will Rockwell Automation, Inc. be responsible or liable for indirect or consequential damages resulting from the use or application of this equipment.The examples and diagrams in this manual are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular installation, Rockwell Automation, Inc. cannot assume responsibility or liability for actual use based on the examples and diagrams.No patent liability is assumed by Rockwell Automation, Inc. with respect to use of information, circuits, equipment, or software described in this manual.Reproduction of the contents of this manual, in whole or in part, without written permission of Rockwell Automation, Inc., is prohibited.Throughout this manual, when necessary, we use notes to make you aware of safety considerations.Allen-Bradley, Rockwell Automation, Rockwell Software, Inc., CompactLogix, ControlLogix, FactoryTalk ME, Kinetix, Logix5000, Point I/O, Panelview Plus, PowerFlex, RSLinx, RSLinx Classic, RSLinx Enterprise, RSLogix, RSLogix 5000, RSLogix 5000 with PhaseManager, RSView Machine Edition, RSView ME, RSView SE, RSView Studio, RSView Enterprise, and TechConnect are trademarks of Rockwell Automation, Inc.Trademarks not belonging to Rockwell Automation are property of their respective companies.WARNINGIdentifies information about practices or circumstances that can cause an explosion in a hazardous environment, which may lead to personal injury or death, property damage, or economic loss.IMPORTANTIdentifies information that is critical for successful application and understanding of the product.ATTENTIONIdentifies information about practices or circumstances that can lead to personal injury or death, property damage, or economic loss. Attentions help you identify a hazard, avoid a hazard, and recognize the consequenceSHOCK HAZARDLabels may be on or inside the equipment, for example, a drive or motor, to alert people that dangerous voltage may be present.BURN HAZARDLabels may be on or inside the equipment, for example, a drive or motor, to alert people that surfaces may reach dangerous temperatures.3Publication IASIMP-QS003B-EN-P - October 20093Where to StartFollow the path that matches your hardware and network configuration.Chapter 12 Create a PanelView Plus ApplicationChapter 13Create a Kinetix 6000 ApplicationChapter 11CCreate a PowerFlex 70 ApplicationChapter 1Prepare the CompactLogix HardwareChapter 2Prepare the Computer and Load Controller FirmwareChapter 3Prepare the Distributed POINT I/O HardwareChapter 6Prepare the Kinetix 6000 Multi-axis Servo Drive SystemChapter 5Prepare the PanelView Plus TerminalChapter 7Configure the EtherNet/IP NetworkChapter 8Configure the DeviceNet NetworkChapter 9Create a Project in RSLogix 5000 Chapter 10Add Distributed Point I/O Modules to the RequiredOptionaldepending on your systemOptionaldepending on your networkRequiredOptionaldepending on your systemRequiredChapter 4Prepare the PowerFlex 70 Drive4 Publication IASIMP-QS003B-EN-P - October 2009Where to StartHow Hardware Is ConnectedThis quick start demonstrates CompactLogix L43 and L45 control systems using a single EtherNet/IP or DeviceNet network for cost-effectiveness and simplified setup. You may choose to use a multiple network system requiring a combination of EtherNet/IP and DeviceNet procedures shown in this quick start.Rockwell Automation also offers many devices other than those in the examples. See your local Rockwell Automation representative for other device options.Option 1: 1768-L43 and 1768-L45 Systems with EtherNet/IP Network 1768-L43 CompactLogix Controller with1768-ENBT EtherNet/IP and 1768-M04SE SERCOS ModulesComputer with Ethernet PortDistributed POINT I/O with 1734-AENT AdapterPowerFlex 70 Drive with 20-COMM-E Adapter2711P PanelView Plus Terminal with Built-in EtherNet/IP PortEthernet Switch1756-CP3 EtherNet/IPSERCOS2094 Kinetix 6000Multi-axis Servo Drive SystemSerialPublication IASIMP-QS003B-EN-P - October 20095Where to StartOption 2: 1768-L43 and L45 Systems with DeviceNet Network1768-L43 CompactLogix Controller with1768-M04SE SERCOS and 1769-SDN DeviceNet ModulesDistributed POINT I/O with 1734-ADN AdapterPowerFlex 70 Drive with 20-COMM-D AdapterDeviceNet Power Supply1606-XLDNET82711P PanelView Plus Terminal ComputerSerialDeviceNetSERCOSDeviceNet with KwikLink flat cable and micro connectors2094 Kinetix 6000Multi-axis Servo Drive System2706-NC131756-CP3

小库

92篇文档

文档介绍: 1768-L43 and 1768-L45 CompactLogix Controllers Quick Start

评论

发表评论
< /205 > 付费下载 ¥ 1 元

Powered by DS文库

Copyright © 联智博库 All Rights Reserved. 鲁ICP备18004091号-4
×
保存成功